PartMeld

ATI Industrial Automation

Nano17 / SI-50-0.5

Model / article: Nano17 / SI-50-0.5

Nano17 / SI-50-0.5 is listed by ATI Industrial Automation in Six-axis force/torque sensors. Published model data includes Product mass: 0.00907 kg; Fx/Fy sensing range: 50 N (maximum). See the specification table for operating conditions and source evidence.

Ultra-compact six-axis transducer. Each record is an explicit published metric calibration; ingress-protected configurations are separate.

Nano17 manufacturer product image
Nano17 manufacturer product image

Product overview

Manufacturer / supplier
ATI Industrial Automation
Series
Nano17 six-axis force/torque sensors
Component type
Six-axis force/torque sensors
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for Nano17 / SI-50-0.5
SpecificationPublished valueConditions and source
Fx/Fy sensing rangeModel-level statement50 NRating: maximum

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Fx, Fy sensing range: 50 N

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Fx, Fy sensing range

Source observed: 2026-09-19View source
Fx/Fy resolutionModel-level statement0.0125 N

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
basis
published calibration resolution
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Fx, Fy resolution: 0.0125 N

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Fx, Fy resolution

Source observed: 2026-09-19View source
Fz sensing rangeModel-level statement70 NRating: maximum

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Fz sensing range: 70 N

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Fz sensing range

Source observed: 2026-09-19View source
Fz resolutionModel-level statement0.0125 N

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
basis
published calibration resolution
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Fz resolution: 0.0125 N

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Fz resolution

Source observed: 2026-09-19View source
Tx/Ty sensing rangeModel-level statement0.5 N·mRating: maximum

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Tx, Ty sensing range: 0.5 N·m

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Tx, Ty sensing range

Source observed: 2026-09-19View source
Tx/Ty resolutionModel-level statement0.0001 N·m

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
basis
published calibration resolution
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Tx, Ty resolution: 0.0001 N·m

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Tx, Ty resolution

Source observed: 2026-09-19View source
Tz sensing rangeModel-level statement0.5 N·mRating: maximum

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Tz sensing range: 0.5 N·m

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Tz sensing range

Source observed: 2026-09-19View source
Tz resolutionModel-level statement0.0625 N·m

rule validated

Operating conditions
axis loading
applied loads must remain within range on every axis
basis
published calibration resolution
calibration
SI-50-0.5
source scope
metric calibration; standard non-IP Nano17 configuration unless separately configured
Source evidence
Nano17 / SI-50-0.5 | Tz resolution: 0.0625 N·m

ATI F/T Catalog pp.22–23 / Nano17 calibration table / Nano17 / SI-50-0.5 / Tz resolution

Source observed: 2026-09-19View source
Product massModel-level statement0.00907 kg

rule validated

Operating conditions
includes
standard interface plates
Source evidence
Nano17 / SI-50-0.5 | Weight: 0.00907 kg

ATI F/T Catalog pp.22–23 / Physical specifications / Nano17 / SI-50-0.5 / Weight

Source observed: 2026-09-19View source
Outer diameterModel-level statement17 mm

rule validated

Operating conditions
excludes
connector and cable features
Source evidence
Nano17 / SI-50-0.5 | Outside diameter: 17 mm

ATI F/T Catalog pp.22–23 / Physical specifications / Nano17 / SI-50-0.5 / Outside diameter

Source observed: 2026-09-19View source
Sensor axial thicknessModel-level statement14.5 mm

rule validated

Operating conditions
includes
standard interface plates
Source evidence
Nano17 / SI-50-0.5 | Height: 14.5 mm

ATI F/T Catalog pp.22–23 / Physical specifications / Nano17 / SI-50-0.5 / Height

Source observed: 2026-09-19View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error