PartMeld

Warner Electric

WR230 VAR00 — configurable model

Model / article: WR230

WR230 VAR00 — configurable model is listed by Warner Electric in Spring-applied brakes. Published model data includes Maximum output speed: 3000 rpm; Operating temperature range: 0 to 40 °C. See the specification table for operating conditions and source evidence.

Published WR230/WR240/WR250 configurable models for mobile robots, cobots and SCARA applications. Each torque, coil-power and length choice stays paired. Model designations are not complete ordering codes. 24 VDC power basis, 0–40°C and 50% maximum duty apply. Illustration is a series reference.

Official WR-Thin series illustration — extracted from PDF p.1
Official WR-Thin series illustration — extracted from PDF p.1

Product overview

Manufacturer / supplier
Warner Electric
Series
WR-Thin VAR00 configurable holding brakes
Component type
Spring-applied brakes
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for WR230 VAR00 — configurable model
SpecificationPublished valueConditions and source
Brake configuration notesModel-level statementConfigurable model; select hub, bore, voltage and mount with manufacturer. No standalone torque guarantee across configurations. No inferred SIL, PL, dual-channel certification, price or delivery time.

rule validated

Source evidence
Ordering and safety scope: Configurable model; select hub, bore, voltage and mount with manufacturer. No standalone torque guarantee across configurations. No inferred SIL, PL, dual-channel certification, price or delivery time.

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Ordering and safety scope

Source observed: 2026-09-20View source
Brake configuration pointsModel-level statement0.5 N·m static torque → 5.3 W, B maximum 20 mm; 1.5 N·m static torque → 11 W, B maximum 28 mm

rule validated

Operating conditions
identity
Choices within one configurable model, not separate published ordering codes
operating points
[{"max_brake_length_B_mm":20,"power_condition":"24 VDC rated power","rated_power_values_W":[5.3],"static_torque_Nm":0.5},{"max_brake_length_B_mm":28,"power_condition":"24 VDC rated power","rated_power_values_W":[11],"static_torque_Nm":1.5}]
power
Two power values require overexcitation; duration and voltage sequence unspecified. Do not mix rows.
voltage VDC
24
Source evidence
Matched torque / power / length choices: 0.5 N·m static torque → 5.3 W, B maximum 20 mm; 1.5 N·m static torque → 11 W, B maximum 28 mm

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Matched torque / power / length choices

Source observed: 2026-09-20View source
Brake disc backlashModel-level statement2.5 °

rule validated

Operating conditions
scope
Disc interface, not robot joint output backlash
Source evidence
Hexagonal-disc backlash: 2.5 °

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Hexagonal-disc backlash

Source observed: 2026-09-20View source
Brake duty cycleModel-level statement50 %

rule validated

Operating conditions
qualifier
maximum
scope
Document does not define cycle period; do not infer continuous operation
Source evidence
Maximum duty cycle: 50 %

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Maximum duty cycle

Source observed: 2026-09-20View source
Brake mounting referenceModel-level statementPCD F nominal 44 mm; screws 3 x M3; inner D maximum 20 mm

rule validated

Operating conditions
options
Alternative mounting, PCD and screws require manufacturer assistance
scope
D is not shaft bore; final hub size, bore, length and position require manufacturer selection
Source evidence
Mounting reference: PCD F nominal 44 mm; screws 3 x M3; inner D maximum 20 mm

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Mounting reference

Source observed: 2026-09-20View source
Brake operationModel-level statementSpring-applied, electrically released static holding/parking brake

rule validated

Operating conditions
scope
Maximum rotational speed is not a dynamic braking speed rating; no stop-energy capability inferred
Source evidence
Operation: Spring-applied, electrically released static holding/parking brake

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Operation

Source observed: 2026-09-20View source
Maximum output speedModel-level statement3000 rpm

rule validated

Operating conditions
scope
Rotational speed; not dynamic braking speed or emergency-stop rating
Source evidence
Maximum speed: 3000 rpm

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Maximum speed

Source observed: 2026-09-20View source
Operating temperature rangeModel-level statement0 to 40 °C

rule validated

Source evidence
Temperature: 0 to 40 °C

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Temperature

Source observed: 2026-09-20View source
Outer diameterModel-level statement50 mm

rule validated

Operating conditions
qualifier
maximum
scope
Brake A, not complete mounting assembly
Source evidence
Maximum brake diameter A: 50 mm

WR230 / MCF P-8824-WE-EN-US 01/25 / PDF p.2 / Maximum brake diameter A

Source observed: 2026-09-20View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error