CSG-50-120-2UH-LW
Model / article: CSG-50-120-2UH-LW
CSG-50-120-2UH-LW is listed by Harmonic Drive LLC in Strain-wave reducers. Published model data includes Rated output torque: 688 Nm (rated); Product mass: 7 kg. See the specification table for operating conditions and source evidence.
CSG-2UH-LW strain-wave reducers
Product overview
- Manufacturer / supplier
- Harmonic Drive LLC
- Series
- CSG-2UH-LW strain-wave reducers
- Component type
- Strain-wave reducers
- Source
- Open published source
Published pricing
No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.
Published specifications
Values are shown as published. Conditions, rating basis and source evidence apply to each value.
Latest source observation: . Observation dates record evidence collection, not supplier re-verification.
| Specification | Published value | Conditions and source |
|---|---|---|
| Allowable momentModel-level statement | 622 Nm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Allowable Moment Load (Mc): 622 Nm CSG-50-120-2UH-LW / Allowable Moment Load (Mc) |
| Average input speedModel-level statement | 2,500 rpm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Ave. Input Speed: 2,500 rpm CSG-50-120-2UH-LW / Ave. Input Speed |
| Average torque limitModel-level statement | 1,057 Nm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Limit for Average Torque: 1,057 Nm CSG-50-120-2UH-LW / Limit for Average Torque |
| Backdriving torqueModel-level statement | 80 Nm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Backdriving Torque: 80 Nm CSG-50-120-2UH-LW / Backdriving Torque |
| Backdriving torqueModel-level statement | 80 Nm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Backdriving torque: 80 Nm CSG-50-120-2UH-LW / Backdriving torque |
| Bearing dynamic loadModel-level statement | 348 10^2 N | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Basic Dynamic Rated Load (C): 348 10^2 N CSG-50-120-2UH-LW / Basic Dynamic Rated Load (C) |
| Bearing pitch diameterModel-level statement | 0.11 m | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Pitch Circle Diameter (dp): 0.11 m CSG-50-120-2UH-LW / Pitch Circle Diameter (dp) |
| Bearing static loadModel-level statement | 602 10^2 N | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Basic Static Rated Load (Co): 602 10^2 N CSG-50-120-2UH-LW / Basic Static Rated Load (Co) |
| Gear ratioModel-level statement | 120 | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Ratio: 120 CSG-50-120-2UH-LW / Ratio |
| Product massModel-level statement | 7 kg | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Mass: 7 kg CSG-50-120-2UH-LW / Mass |
| Product massModel-level statement | 7 kg | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Mass: 7 kg CSG-50-120-2UH-LW / Mass |
| Moment stiffnessModel-level statement | 140 10^4 Nm / rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Moment Stiffness (Km): 140 10^4 Nm / rad CSG-50-120-2UH-LW / Moment Stiffness (Km) |
| Moment stiffnessModel-level statement | 140 10^4 Nm/rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Output moment stiffness: 140 10^4 Nm/rad CSG-50-120-2UH-LW / Output moment stiffness |
| Momentary peak torqueModel-level statement | 2,678 NmRating: peak | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Limit for Momentary Peak Torque: 2,678 Nm CSG-50-120-2UH-LW / Limit for Momentary Peak Torque |
| Momentary peak torqueModel-level statement | 2,678 NmRating: peak | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Limit for momentary peak torque: 2,678 Nm CSG-50-120-2UH-LW / Limit for momentary peak torque |
| Positioning accuracyModel-level statement | 1 arc minRating: minimum | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Standard Accuracy: 1 arc min CSG-50-120-2UH-LW / Standard Accuracy |
| Positioning accuracyModel-level statement | 1 arcmin | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Standard accuracy: 1 arcmin CSG-50-120-2UH-LW / Standard accuracy |
| Rated output torqueModel-level statement | 688 NmRating: rated | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Rated Torque L10: 688 Nm CSG-50-120-2UH-LW / Rated Torque L10 |
| Rated output torqueModel-level statement | 688 NmRating: rated | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | Rated torque L10: 688 Nm CSG-50-120-2UH-LW / Rated torque L10 |
| Repeated peak torqueModel-level statement | 1,404 NmRating: peak | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Limit for Repeated Peak Torque: 1,404 Nm CSG-50-120-2UH-LW / Limit for Repeated Peak Torque |
| Repeated peak torqueModel-level statement | 1,404 NmRating: peak | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Limit for repeated peak torque: 1,404 Nm CSG-50-120-2UH-LW / Limit for repeated peak torque |
| Starting torqueModel-level statement | 57 Ncm | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | Starting Torque: 57 Ncm CSG-50-120-2UH-LW / Starting Torque |
| Stiffness transition torque 1Model-level statement | 108 Nm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | T1: 108 Nm CSG-50-120-2UH-LW / T1 |
| Stiffness transition torque 2Model-level statement | 382 Nm | rule validated Operating conditions
Source evidenceCSG-50-120-2UH-LW | T2: 382 Nm CSG-50-120-2UH-LW / T2 |
| Torsional stiffness k1Model-level statement | 25 10^4 Nm / rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | K1: 25 10^4 Nm / rad CSG-50-120-2UH-LW / K1 |
| Torsional stiffness k1Model-level statement | 25 10^4 Nm/rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | K1 torsional stiffness: 25 10^4 Nm/rad CSG-50-120-2UH-LW / K1 torsional stiffness |
| Torsional stiffness k2Model-level statement | 40 10^4 Nm / rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | K2: 40 10^4 Nm / rad CSG-50-120-2UH-LW / K2 |
| Torsional stiffness k2Model-level statement | 40 10^4 Nm/rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | K2 torsional stiffness: 40 10^4 Nm/rad CSG-50-120-2UH-LW / K2 torsional stiffness |
| Torsional stiffness k3Model-level statement | 44 10^4 Nm / rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | K3: 44 10^4 Nm / rad CSG-50-120-2UH-LW / K3 |
| Torsional stiffness k3Model-level statement | 44 10^4 Nm/rad | extracted Operating conditions
Source evidenceCSG-50-120-2UH-LW | K3 torsional stiffness: 44 10^4 Nm/rad CSG-50-120-2UH-LW / K3 torsional stiffness |
Technical documents and resources
Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.