Model / article: V20-RO-P3-R-M-M2-AL-P1-40

Professional / 632-91183 is listed by SensoPart in Robot vision. Published model data includes Communication interface: TCP/IP, Profinet, EtherNet/IP, sFTP, SMB, FTP, Service Port; Overall length: 45.0. See the specification table for operating conditions and source evidence.

Monochrome 2D robot-guidance vision sensor with integrated distance measurement; Professional variant.

VISOR Robotic +Z representative product image linked on exact-model page
VISOR Robotic +Z representative product image linked on exact-model page

Product overview

Manufacturer / supplier
SensoPart
Series
VISOR Robotic +Z
Component type
Robot vision
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for Professional / 632-91183
SpecificationPublished valueConditions and source
Communication interfaceModel-level statementTCP/IP, Profinet, EtherNet/IP, sFTP, SMB, FTP, Service Port

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Network protocol: TCP/IP, Profinet, EtherNet/IP, sFTP, SMB, FTP, Service Port

attributeTable[2]/tbody/tr[1]

Source observed: 2026-10-14View source
Overall lengthModel-level statement45.0

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Length [mm]: 45.0

attributeTable[4]/tbody/tr[2]

Source observed: 2026-10-14View source
Sensor connectorModel-level statementConnection name: LAN; - Number of pins: 4; - Coding: D; - Thread: M12x1; - Material: Metal; - Type: Socket

rule validated

Operating conditions
connection
LAN
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Connection name: Connection name: LAN; - Number of pins: 4; - Coding: D; - Thread: M12x1; - Material: Metal; - Type: Socket

attributeTable[4]/tbody/tr[13..18]

Source observed: 2026-10-14View source
Sensor connectorModel-level statementConnection name: Supply; - Number of pins: 12; - Coding: A; - Thread: M12x1; - Material: Metal; - Type: Plug

rule validated

Operating conditions
connection
Supply
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Connection name: Connection name: Supply; - Number of pins: 12; - Coding: A; - Thread: M12x1; - Material: Metal; - Type: Plug

attributeTable[4]/tbody/tr[7..12]

Source observed: 2026-10-14View source
Sensor current consumptionModel-level statement350Rating: typical

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Typical current draw [mA]: 350

attributeTable[3]/tbody/tr[4]

Source observed: 2026-10-14View source
Sensor materialModel-level statementAluminum (cast)

rule validated

Operating conditions
component
housing
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Housing material: Aluminum (cast)

attributeTable[4]/tbody/tr[6]

Source observed: 2026-10-14View source
Sensor materialModel-level statementPMMA

rule validated

Operating conditions
component
front panel
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Front panel material: PMMA

attributeTable[4]/tbody/tr[5]

Source observed: 2026-10-14View source
Sensor supply voltageModel-level statement18 ... 30

rule validated

Operating conditions
supply requirement
The device must be supplied by a "Class 2" power supply unit.
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Operating voltage UB [V DC]: 18 ... 30

attributeTable[3]/tbody/tr[3]

Source observed: 2026-10-14View source
Vision additional functionsModel-level statementArchiving, Image transmission, individual overlays, Multiple image acquisition, Multiple detection for contour and pattern matching detector, Multiple detection for detector contour (3D), Job checksum, Conditional executions

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Additional functions: Archiving, Image transmission, individual overlays, Multiple image acquisition, Multiple detection for contour and pattern matching detector, Multiple detection for detector contour (3D), Job checksum, Conditional executions

attributeTable[2]/tbody/tr[9]

Source observed: 2026-10-14View source
Vision calibration modesModel-level statementBoard (measurement), Board (robotics), Hand-Eye (6-axis robot, SCARA and gantry robot), Base-Eye (6-axis robot,, SCARA and gantry robot), Scaling (measurement), Point pair list (robotics)

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Calibration: Board (measurement), Board (robotics), Hand-Eye (6-axis robot, SCARA and gantry robot), Base-Eye (6-axis robot,, SCARA and gantry robot), Scaling (measurement), Point pair list (robotics)

attributeTable[2]/tbody/tr[10]

Source observed: 2026-10-14View source
Vision distance spot sizeModel-level statement2 x 5

rule validated

Operating conditions
at distance mm
150
raw condition
À une distance de 150 mm
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Light spot size [mm]: 2 x 5

attributeTable[1]/tbody/tr[3]

Source observed: 2026-10-14View source
Vision ethernet rateModel-level statement100

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Ethernet transmission rate [Mbit/s]: 100

attributeTable[3]/tbody/tr[20]

Source observed: 2026-10-14View source
Vision focal lengthModel-level statement12.0

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Focal length [mm]: 12.0

attributeTable[1]/tbody/tr[18]

Source observed: 2026-10-14View source
Vision focus driveModel-level statementMotorized

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Focus drive: Motorized

attributeTable[1]/tbody/tr[22]

Source observed: 2026-10-14View source
Vision image chip technologyModel-level statementCMOS

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Imaging chip technology: CMOS

attributeTable[1]/tbody/tr[14]

Source observed: 2026-10-14View source
Vision image resolutionModel-level statement1440 x 1080

rule validated

Operating conditions
image chip type
Monochrome
not rgb
true
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Number of pixels (H x V) [px]: 1440 x 1080

attributeTable[1]/tbody/tr[13]

Source observed: 2026-10-14View source
Vision ingress protectionModel-level statementIP 65, IP 67

rule validated

Operating conditions
published condition
For C-mount devices, only in combination with protective tube
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Protection class: IP 65, IP 67

attributeTable[4]/tbody/tr[24]

Source observed: 2026-10-14View source
Vision max detectorsModel-level statement255

rule validated

Operating conditions
scope
per job; short description confirms 255 jobs each with 255 detectors
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Max. number of detectors: 255

attributeTable[2]/tbody/tr[4]

Source observed: 2026-10-14View source
Vision max jobsModel-level statement255

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Max. number of jobs: 255

attributeTable[2]/tbody/tr[3]

Source observed: 2026-10-14View source
Vision minimum field of viewModel-level statement10 x 8

rule validated

Operating conditions
distance not specified for minimum fov
true
minimum
true
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Min. field of view (X x Y) [mm]: 10 x 8

attributeTable[1]/tbody/tr[24]

Source observed: 2026-10-14View source
Vision opening angleModel-level statement24.0

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Opening angle [°]: 24.0

attributeTable[1]/tbody/tr[19]

Source observed: 2026-10-14View source
Vision optical operating distanceModel-level statement25 ... 10,000

rule validated

Operating conditions
measurement
Optical imaging operating distance, not +Z distance measurement range
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Operating distance [mm]: 25 ... 10,000

attributeTable[1]/tbody/tr[17]

Source observed: 2026-10-14View source
Vision pixel sizeModel-level statement3.45

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Pixel size [µm]: 3.45

attributeTable[1]/tbody/tr[15]

Source observed: 2026-10-14View source
Vision robotic functionsModel-level statementGripper clearance check, Result offset, image coordinates, Result offset 2D, Result offset 3D

rule validated

Operating conditions
3D pose function does not mean dense 3D camera
true
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Robotic functions: Gripper clearance check, Result offset, image coordinates, Result offset 2D, Result offset 3D

attributeTable[2]/tbody/tr[8]

Source observed: 2026-10-14View source
Vision storage temperatureModel-level statement-20 ... 60

rule validated

Operating conditions
humidity
< 95 % humidity, non-condensing
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Ambient temperature: storage [°C]: -20 ... 60

attributeTable[4]/tbody/tr[22]

Source observed: 2026-10-14View source
Vision system typeModel-level statement2D vision-guided robotics with integrated distance measurement

rule validated

Operating conditions
classification
CMP-370; not dense 3D imaging or RGB camera
Source evidence
The VISOR Robotic +Z combines the strengths of 2D vision-guided robotics with precise distance measurement for large working distances.

VISOR Robotic +Z description

Source observed: 2026-10-14View source
Vision warmup timeModel-level statement20

rule validated

Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Warm-up time [Min.]: 20

attributeTable[3]/tbody/tr[1]

Source observed: 2026-10-14View source
Working distanceModel-level statement150 ... 2,500

rule validated

Operating conditions
measurement
Integrated distance sensor; distinct from optical operating distance 25 ... 10,000 mm
warmup time min
20
Source evidence
V20-RO-P3-R-M-M2-AL-P1-40 [632-91183] | Working range [mm]: 150 ... 2,500

attributeTable[1]/tbody/tr[2]

Source observed: 2026-10-14View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error