PartMeld

Hesai Technology

JT128

Model / article: JT128

JT128 is listed by Hesai Technology in Robot LiDAR. Published model data includes Communication interface: Standard 100Base-TX; Ingress protection rating: IP6K7. See the specification table for operating conditions and source evidence.

JT128

Product image
Product image

Product overview

Manufacturer / supplier
Hesai Technology
Series
JT128
Component type
Robot LiDAR
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for JT128
SpecificationPublished valueConditions and source
Communication interfaceModel-level statementStandard 100Base-TX

rule validated

Operating conditions
applicability
1 Introduction 1.1 Applicability This manual applies to the following versions: Software 15.AF.B0.00.02.Y or later Firmware of Sensor 2.b.0692 or later Firmware of Controller 1.b.0028 or later
clock source
GNSS/PTP (1588v2 over UDP/IP, 1588v2 over L2, 802.1AS, 802.1AS Automotive)
configuration
95-degree vertical FOV configuration described in manual; verify firmware applicability
model
JT128
source revision
J01-en-261010
Source evidence
Data transmission Standard 100Base-TX

PDF page 21 / Data transmission

Source observed: 2026-10-16View source
Ingress protection ratingModel-level statementIP6K7

rule validated

Operating conditions
applicability
1 Introduction 1.1 Applicability This manual applies to the following versions: Software 15.AF.B0.00.02.Y or later Firmware of Sensor 2.b.0692 or later Firmware of Controller 1.b.0028 or later
configuration
95-degree vertical FOV configuration described in manual; verify firmware applicability
model
JT128
source revision
J01-en-261010
Source evidence
Ingress protection IP6K7

PDF page 20 / Ingress protection

Source observed: 2026-10-16View source
Lidar channel countModel-level statement128 Channels

rule validated

Operating conditions
source scope
Current model-specific website tab; published typical values under unspecified test conditions
Source evidence
128 Channels

#tab-jt128 / Channels

Source observed: 2026-10-15View source
Lidar point rateModel-level statement1,152,000 pts/s [Single Return] POINT RATE

rule validated

Operating conditions
return mode
Single Return
source scope
Current model-specific website tab; published typical values under unspecified test conditions
Source evidence
1,152,000 pts/s [Single Return] POINT RATE

#tab-jt128 / POINT RATE

Source observed: 2026-10-15View source
Lidar powerModel-level statement8.4 WRating: typical

rule validated

Operating conditions
ambient temperature
25°C
applicability
1 Introduction 1.1 Applicability This manual applies to the following versions: Software 15.AF.B0.00.02.Y or later Firmware of Sensor 2.b.0692 or later Firmware of Controller 1.b.0028 or later
configuration
95-degree vertical FOV configuration described in manual; verify firmware applicability
excludes
accessories such as connection box
external supply minimum
2.6 A, 30 W
frame rate
10 Hz
model
JT128
rating
typical
source revision
J01-en-261010
Source evidence
Power consumption ④ 8.4 W

PDF page 21 / Power consumption

Source observed: 2026-10-16View source
Lidar range 10 reflectivityModel-level statement40 m @10% Reflectivity [60 m Max] Ranging Capability

rule validated

Operating conditions
maximum range not equivalent
60 m Max has no target condition; not indexed as 10% range
reflectivity
10%
source scope
Current model-specific website tab; published typical values under unspecified test conditions
Source evidence
40 m @10% Reflectivity [60 m Max] Ranging Capability

#tab-jt128 / Ranging Capability

Source observed: 2026-10-15View source
Lidar return modeModel-level statementReturn mode Single return:   First/Strongest/Last Dual return:   Last and Strongest (default) / Last and First / First and Strongest

rule validated

Operating conditions
model
JT128
model scope
Only configuration/revision described in linked document
source document
https://www.hesaitech.com/wp-content/uploads/2026/10/JT128_User_Manual_J01-en-261010.pdf
Source evidence
Return mode Single return:   First/Strongest/Last Dual return:   Last and Strongest (default) / Last and First / First and Strongest

PDF page 20 / Return mode

Source observed: 2026-10-16View source
Lidar wavelengthModel-level statement905 nm

rule validated

Operating conditions
applicability
1 Introduction 1.1 Applicability This manual applies to the following versions: Software 15.AF.B0.00.02.Y or later Firmware of Sensor 2.b.0692 or later Firmware of Controller 1.b.0028 or later
configuration
95-degree vertical FOV configuration described in manual; verify firmware applicability
model
JT128
source revision
J01-en-261010
Source evidence
Wavelength 905 nm

PDF page 20 / Wavelength

Source observed: 2026-10-16View source
Operating temperature rangeModel-level statement-20°C to 65°C

rule validated

Operating conditions
applicability
1 Introduction 1.1 Applicability This manual applies to the following versions: Software 15.AF.B0.00.02.Y or later Firmware of Sensor 2.b.0692 or later Firmware of Controller 1.b.0028 or later
configuration
95-degree vertical FOV configuration described in manual; verify firmware applicability
model
JT128
source revision
J01-en-261010
temperature basis
ambient air; surface and internal temperatures can exceed ambient
Source evidence
Operating temperature ⑤ -20°C to 65°C

PDF page 21 / Operating temperature

Source observed: 2026-10-16View source
Supply voltage rangeModel-level statementDC 9 to 32 V

rule validated

Operating conditions
applicability
1 Introduction 1.1 Applicability This manual applies to the following versions: Software 15.AF.B0.00.02.Y or later Firmware of Sensor 2.b.0692 or later Firmware of Controller 1.b.0028 or later
configuration
95-degree vertical FOV configuration described in manual; verify firmware applicability
measurement location
lidar connector
model
JT128
source revision
J01-en-261010
Source evidence
Rated voltage range ③ DC 9 to 32 V

PDF page 21 / Rated voltage range

Source observed: 2026-10-16View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error