PartMeld

IPR Intelligente Peripherien für Roboter GmbH

TK-300-R St SV

Model / article: 15030214

TK-300-R St SV is listed by IPR Intelligente Peripherien für Roboter GmbH in Robot tool changers. Published model data includes Product mass: 25 kg. See the specification table for operating conditions and source evidence.

Robot-side and tool-side articles indexed separately. Coupled ratings require the correct mate and stated load-centre/pressure conditions. Conflicting brochure/webpage fields are withheld, not guessed.

TK-300-R St SV — robot side manufacturer illustration (similar)
TK-300-R St SV — robot side manufacturer illustration (similar)

Product overview

Manufacturer / supplier
IPR Intelligente Peripherien für Roboter GmbH
Series
TK robot tool-changer components
Component type
Robot tool changers
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for TK-300-R St SV
SpecificationPublished valueConditions and source
Product massModel-level statement25 kg

rule validated

Operating conditions
scope
robot side only; no mating component, attached tool or accessory mass inferred
Source evidence
Weight: 25 kg

Article 15030214 / TK-300-R St SV / technical table / Weight

Source observed: 2026-09-20View source
Tool changer com distanceModel-level statement500 mm

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Max. Distance to centre of mass: 500 mm

Article 15030214 / TK-300-R St SV / technical table / Max. Distance to centre of mass

Source observed: 2026-09-20View source
Tool changer component sideModel-level statementrobot side

rule validated

Operating conditions
identity
Separate article; not complete coupled tool changer
Source evidence
Component side: robot side

Article 15030214 / TK-300-R St SV / technical table / Component side

Source observed: 2026-09-20View source
Tool changer compressive forceModel-level statement80,000 N

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Max. compressive force Fd: 80,000 N

Article 15030214 / TK-300-R St SV / technical table / Max. compressive force Fd

Source observed: 2026-09-20View source
Tool changer configuration scopeModel-level statementArticle is robot side. Manufacturer illustration is similar, not an exact configuration guarantee. Optional electrical/hydraulic modules and sensors are not assumed included. Loss-of-pressure retention or double-lock wording is not SIL/PL certification.

rule validated

Source evidence
Configuration scope: Article is robot side. Manufacturer illustration is similar, not an exact configuration guarantee. Optional electrical/hydraulic modules and sensors are not assumed included. Loss-of-pressure retention or double-lock wording is not SIL/PL certification.

Article 15030214 / TK-300-R St SV / technical table / Configuration scope

Source observed: 2026-09-20View source
Tool changer coupling travelModel-level statement54.5 mm

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
scope
Coupling travel; not overall coupled height
Source evidence
Coupling path: 54.5 mm

Article 15030214 / TK-300-R St SV / technical table / Coupling path

Source observed: 2026-09-20View source
Tool changer environmentModel-level statement5 °C (41 °F) to +80 °C (+176 °F)

rule validated

Source evidence
Ambient temperature: 5 °C (41 °F) to +80 °C (+176 °F)

Article 15030214 / TK-300-R St SV / technical table / Ambient temperature

Source observed: 2026-09-20View source
Tool changer flangeModel-level statement300 mm

rule validated

Operating conditions
scope
robot side page; complete compatibility requires drawings and correct mating part
Source evidence
Article connection flange: 300 mm

Article 15030214 / TK-300-R St SV / technical table / Article connection flange

Source observed: 2026-09-20View source
Tool changer joining forceModel-level statement330 N

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Joining force in joining direction: 330 N

Article 15030214 / TK-300-R St SV / technical table / Joining force in joining direction

Source observed: 2026-09-20View source
Tool changer locking offsetModel-level statement3 mm

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Max. permissible offset while locking: 3 mm

Article 15030214 / TK-300-R St SV / technical table / Max. permissible offset while locking

Source observed: 2026-09-20View source
Tool changer max moment xyModel-level statement15,000 Nm

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Max. moment Mx, My: 15,000 Nm

Article 15030214 / TK-300-R St SV / technical table / Max. moment Mx, My

Source observed: 2026-09-20View source
Tool changer max moment zModel-level statement9,100 Nm

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Max. moment Mz: 9,100 Nm

Article 15030214 / TK-300-R St SV / technical table / Max. moment Mz

Source observed: 2026-09-20View source
Tool changer operating pressureModel-level statementNominal 6 bar (87 psi); min 4.5 bar (65.3 psi); max 8 bar (116 psi)

rule validated

Operating conditions
scope
Operating assembly requirement; passive tool side does not itself contain the robot-side actuator
Source evidence
Operating pressure: Nominal 6 bar (87 psi); min 4.5 bar (65.3 psi); max 8 bar (116 psi)

Article 15030214 / TK-300-R St SV / technical table / Operating pressure

Source observed: 2026-09-20View source
Tool changer recommended payloadModel-level statement800 kg

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Recommended handling weight, not a standalone guaranteed robot payload
Source evidence
Recommended handling weight: 800 kg

Article 15030214 / TK-300-R St SV / technical table / Recommended handling weight

Source observed: 2026-09-20View source
Tool changer repeatabilityModel-level statement0.05 mm

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Repeatability: 0.05 mm

Article 15030214 / TK-300-R St SV / technical table / Repeatability

Source observed: 2026-09-20View source
Tool changer tensile forceModel-level statement60,000 N

rule validated

Operating conditions
assembly
Correct matched and locked robot/tool-side assembly required; article is robot side, not complete system
brochure page
25
centre of mass limit
500 mm
corroborating document
https://en.iprworldwide.com/wp-content/uploads/2021/11/IPR_Product-brochure_Tool-changers_en.pdf
pressure
6 bar (87 psi)
qualification
Catalog maxima are not guaranteed simultaneously under arbitrary acceleration. Moment static/dynamic basis is unspecified.
Source evidence
Max. tensile force Fz: 60,000 N

Article 15030214 / TK-300-R St SV / technical table / Max. tensile force Fz

Source observed: 2026-09-20View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error