PartMeld

Rollvis SA

RVI 60 x 5 (4 starts)

Model / article: RVI 60 x 5 (4 starts)

RVI 60 x 5 (4 starts) is listed by Rollvis SA in Planetary roller screws. Published model data includes Helix angle: 1,52 °; Minimum external nut diameter D1: 108 mm. See the specification table for operating conditions and source evidence.

Published size/lead/start configurations, not complete ordering codes. Nut design, preload, accuracy grade, thread direction, seals, shaft length and end machining require configuration. Load capacities are not actuator thrust ratings.

Family image
Family image

Product overview

Manufacturer / supplier
Rollvis SA
Series
Rollvis RVI inverted roller screws
Component type
Planetary roller screws
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for RVI 60 x 5 (4 starts)
SpecificationPublished valueConditions and source
Helix angleModel-level statement1,52 °

rule validated

Operating conditions
architecture
inverted
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Helix angle: 1,52 ° | {}

PDF p.52 / RVI 60 x 5 (4 starts) / Helix angle

Source observed: 2026-09-14View source
Minimum external nut diameter D1Model-level statement108 mm

rule validated

Operating conditions
architecture
inverted
dimension reference
catalog drawing; verify final configured drawing
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Minimum external nut diameter D1: 108 mm | {'dimension_reference': 'catalog drawing; verify final configured drawing'}

PDF p.52 / RVI 60 x 5 (4 starts) / Minimum external nut diameter D1

Source observed: 2026-09-14View source
Nominal nut diameter d00Model-level statement90 mm

rule validated

Operating conditions
architecture
inverted
dimension reference
catalog drawing; verify final configured drawing
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Nominal nut diameter d00: 90 mm | {'dimension_reference': 'catalog drawing; verify final configured drawing'}

PDF p.52 / RVI 60 x 5 (4 starts) / Nominal nut diameter d00

Source observed: 2026-09-14View source
Maximum axial backlash (source unit unspecified)Model-level statement0,03Rating: maximum

extracted

Operating conditions
architecture
inverted
availability
can be reduced on demand
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
unit note
unit not printed in the source column; confirm with manufacturer
Source evidence
RVI 60 x 5 (4 starts) | Max axial backlash: 0,03 (unit not printed)

PDF p.52 / RVI 60 x 5 (4 starts) / Max axial backlash

Source observed: 2026-09-14View source
Direct efficiencyModel-level statement0,78 1

rule validated

Operating conditions
architecture
inverted
direction
rotary to linear
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating note
catalog estimate; preload and operating conditions affect actual efficiency
Source evidence
RVI 60 x 5 (4 starts) | Direct efficiency: 0,78 1 | {'direction': 'rotary to linear', 'rating_note': 'catalog estimate; preload and operating conditions affect actual efficiency'}

PDF p.52 / RVI 60 x 5 (4 starts) / Direct efficiency

Source observed: 2026-09-14View source
Dynamic axial load capacity CaModel-level statement259,3 kN

rule validated

Operating conditions
architecture
inverted
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating basis
rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit
Source evidence
RVI 60 x 5 (4 starts) | Dynamic load capacity Ca: 259,3 kN | {'nut_type': 'single', 'rating_basis': 'rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit'}

PDF p.52 / RVI 60 x 5 (4 starts) / Dynamic load capacity Ca

Source observed: 2026-09-14View source
External screw diameter d1Model-level statement60,43 mm

rule validated

Operating conditions
architecture
inverted
dimension reference
catalog drawing; verify final configured drawing
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | External screw diameter d1: 60,43 mm | {'dimension_reference': 'catalog drawing; verify final configured drawing'}

PDF p.52 / RVI 60 x 5 (4 starts) / External screw diameter d1

Source observed: 2026-09-14View source
Indirect efficiencyModel-level statement0,71 1

rule validated

Operating conditions
architecture
inverted
direction
linear to rotary
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating note
catalog estimate; not proof of system backdrivability
Source evidence
RVI 60 x 5 (4 starts) | Indirect efficiency: 0,71 1 | {'direction': 'linear to rotary', 'rating_note': 'catalog estimate; not proof of system backdrivability'}

PDF p.52 / RVI 60 x 5 (4 starts) / Indirect efficiency

Source observed: 2026-09-14View source
Lead (travel per revolution)Model-level statement5 mm/rev

rule validated

Operating conditions
architecture
inverted
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Lead P (travel per revolution): 5 mm/rev | {}

PDF p.52 / RVI 60 x 5 (4 starts) / Lead P (travel per revolution)

Source observed: 2026-09-14View source
Nominal screw diameter d0Model-level statement60 mm

rule validated

Operating conditions
architecture
inverted
dimension reference
catalog drawing; verify final configured drawing
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Nominal screw diameter d0: 60 mm | {'dimension_reference': 'catalog drawing; verify final configured drawing'}

PDF p.52 / RVI 60 x 5 (4 starts) / Nominal screw diameter d0

Source observed: 2026-09-14View source
Screw reference diameter DModel-level statement60 mm

rule validated

Operating conditions
architecture
inverted
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Reference diameter D: 60 mm | {}

PDF p.52 / RVI 60 x 5 (4 starts) / Reference diameter D

Source observed: 2026-09-14View source
Rigidity factor FkModel-level statement112,7 N^(2/3)/µm

rule validated

Operating conditions
architecture
inverted
definition
nonlinear rigidity factor, not assembled axial stiffness
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Rigidity factor Fk: 112,7 N^(2/3)/µm | {'nut_type': 'single', 'definition': 'nonlinear rigidity factor, not assembled axial stiffness'}

PDF p.52 / RVI 60 x 5 (4 starts) / Rigidity factor Fk

Source observed: 2026-09-14View source
Thread root diameter d2Model-level statement59,42 mm

rule validated

Operating conditions
architecture
inverted
dimension reference
catalog drawing; verify final configured drawing
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Thread root diameter d2: 59,42 mm | {'dimension_reference': 'catalog drawing; verify final configured drawing'}

PDF p.52 / RVI 60 x 5 (4 starts) / Thread root diameter d2

Source observed: 2026-09-14View source
Static axial load capacity C0aModel-level statement676,9 kN

rule validated

Operating conditions
architecture
inverted
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Static load capacity C0a: 676,9 kN | {'nut_type': 'single'}

PDF p.52 / RVI 60 x 5 (4 starts) / Static load capacity C0a

Source observed: 2026-09-14View source
Thread startsModel-level statement4 1

rule validated

Operating conditions
architecture
inverted
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RVI 60 x 5 (4 starts) | Number of starts N: 4 1 | {}

PDF p.52 / RVI 60 x 5 (4 starts) / Number of starts N

Source observed: 2026-09-14View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.