PhoXi 3D Scanner XL Gen2
Model / article: PhoXi 3D Scanner XL Gen2
PhoXi 3D Scanner XL Gen2 is listed by Photoneo in 3D robot cameras. Published model data includes Product mass: 1200 g; Dimensions: 953 x 68 x 86 mm. See the specification table for operating conditions and source evidence.
PhoXi 3D Scanner Gen2

Product overview
- Manufacturer / supplier
- Photoneo
- Series
- PhoXi 3D Scanner Gen2
- Component type
- 3D robot cameras
- Source
- Open published source
Published pricing
No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.
Published specifications
Values are shown as published. Conditions, rating basis and source evidence apply to each value.
Latest source observation: . Observation dates record evidence collection, not supplier re-verification.
| Specification | Published value | Conditions and source |
|---|---|---|
| Depth resolutionModel-level statement | 3.2 Mpix (2064 x 1544) | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Depth Map Resolution: 3.2 Mpix (2064 x 1544) #panel-11-11-4 |
| DimensionsModel-level statement | 953 x 68 x 86 mm | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Dimensions: 953 x 68 x 86 mm #panel-11-11-4 |
| Product massModel-level statement | 1200 g | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Weight: 1200 g #panel-11-11-4 |
| Nominal supply voltageModel-level statement | PoE or 24V | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Power: PoE or 24V #panel-11-11-4 |
| Operating temperature rangeModel-level statement | Full: 0 - 40 °C (32 - 104 °F) Optimal: 22 - 25 °C (71.6 - 77 °F) | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Temperature working range: Full: 0 - 40 °C (32 - 104 °F) Optimal: 22 - 25 °C (71.6 - 77 °F) #panel-11-11-4 |
| Sensor interfaceModel-level statement | 1 Gbit Ethernet | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Data connection: 1 Gbit Ethernet #panel-11-11-4 |
| Vision acquisition timeModel-level statement | From 190 msRating: minimum | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Acquisition time: From 190 ms #panel-11-11-4 |
| Vision baselineModel-level statement | 850.0 mm | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Baseline: 850.0 mm #panel-11-11-4 |
| Vision global planarityModel-level statement | 2.90Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Global planarity (mm): 2.90 #panel-11-11-4 |
| Vision global planarityModel-level statement | 0.70Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Global planarity (mm): 0.70 #panel-11-11-4 |
| Vision global planarityModel-level statement | 1.38Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Global planarity (mm): 1.38 #panel-11-11-4 |
| Vision ingress protectionModel-level statement | IP65 | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | IP rating: IP65 #panel-11-11-4 |
| Vision laser colorModel-level statement | Red | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Projection unit laser color: Red #panel-11-11-4 |
| Vision local planarityModel-level statement | 0.59Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Local planarity (mm): 0.59 #panel-11-11-4 |
| Vision local planarityModel-level statement | 1.25Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Local planarity (mm): 1.25 #panel-11-11-4 |
| Vision local planarityModel-level statement | 0.30Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Local planarity (mm): 0.30 #panel-11-11-4 |
| Vision output dataModel-level statement | 3D points (x y z), Normals (x y z), Depth Map (z), Texture (grayscale intensity), Confidence | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Output data: 3D points (x y z), Normals (x y z), Depth Map (z), Texture (grayscale intensity), Confidence #panel-11-11-4 |
| Vision point spacingModel-level statement | 1.62Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Point-to-point distance (mm): 1.62 #panel-11-11-4 |
| Vision point spacingModel-level statement | 0.72Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Point-to-point distance (mm): 0.72 #panel-11-11-4 |
| Vision point spacingModel-level statement | 1.00Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Point-to-point distance (mm): 1.00 #panel-11-11-4 |
| Vision processorModel-level statement | NVIDIA Jetson TX2 | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Processing unit: NVIDIA Jetson TX2 #panel-11-11-4 |
| Vision relative distance accuracyModel-level statement | 1.60Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Relative distance accuracy (‰): 1.60 #panel-11-11-4 |
| Vision relative distance accuracyModel-level statement | 1.60Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Relative distance accuracy (‰): 1.60 #panel-11-11-4 |
| Vision relative distance accuracyModel-level statement | 1.60Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Relative distance accuracy (‰): 1.60 #panel-11-11-4 |
| Vision scan areaModel-level statement | 2019 x 1495 mm | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Scanning area (sweet spot): 2019 x 1495 mm #panel-11-11-4 |
| Vision scanning timeModel-level statement | From 250msRating: minimum | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | Scanning time: From 250ms #panel-11-11-4 |
| Vision system typeModel-level statement | Structured Light | rule validated Source evidencePhoXi 3D Scanner XL Gen2 | 3D sensing technology: Structured Light #panel-11-11-4 |
| Vision temporal noiseModel-level statement | 0.11Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Temporal noise (mm): 0.11 #panel-11-11-4 |
| Vision temporal noiseModel-level statement | 0.21Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Temporal noise (mm): 0.21 #panel-11-11-4 |
| Vision temporal noiseModel-level statement | 0.45Rating: maximum | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Temporal noise (mm): 0.45 #panel-11-11-4 |
| Working distanceModel-level statement | 1680 - 2331 - 3780 mm | rule validated Operating conditions
Source evidencePhoXi 3D Scanner XL Gen2 | Scanning range (near - sweet - far): 1680 - 2331 - 3780 mm #panel-11-11-4 |
Technical documents and resources
Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.