PartMeld

Rollvis SA

RV 12 x 8 (5 starts)

Model / article: RV 12 x 8 (5 starts)

RV 12 x 8 (5 starts) is listed by Rollvis SA in Planetary roller screws. Published model data includes Helix angle: 11,98 °; Direct efficiency: 0,86 1. See the specification table for operating conditions and source evidence.

Published size/lead/start configurations, not complete ordering codes. Nut design, preload, accuracy grade, thread direction, seals, shaft length and end machining require configuration. Load capacities are not actuator thrust ratings.

Family image
Family image

Product overview

Manufacturer / supplier
Rollvis SA
Series
Rollvis RV planetary roller screws
Component type
Planetary roller screws
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for RV 12 x 8 (5 starts)
SpecificationPublished valueConditions and source
Helix angleModel-level statement11,98 °

rule validated

Operating conditions
architecture
standard planetary
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Helix angle: 11,98 ° | {}

PDF p.26 / RV 12 x 8 (5 starts) / Helix angle

Source observed: 2026-09-14View source
Maximum axial backlash (source unit unspecified)Model-level statement0,05Rating: maximum

extracted

Operating conditions
architecture
standard planetary
availability
can be reduced on demand
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
unit note
unit not printed in the source column; confirm with manufacturer
Source evidence
RV 12 x 8 (5 starts) | Max axial backlash: 0,05 (unit not printed)

PDF p.26 / RV 12 x 8 (5 starts) / Max axial backlash

Source observed: 2026-09-14View source
Direct efficiencyModel-level statement0,86 1

rule validated

Operating conditions
architecture
standard planetary
direction
rotary to linear
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating note
catalog estimate; preload and operating conditions affect actual efficiency
Source evidence
RV 12 x 8 (5 starts) | Direct efficiency: 0,86 1 | {'direction': 'rotary to linear', 'rating_note': 'catalog estimate; preload and operating conditions affect actual efficiency'}

PDF p.26 / RV 12 x 8 (5 starts) / Direct efficiency

Source observed: 2026-09-14View source
Dynamic axial load capacity CaModel-level statement18,6 kN

rule validated

Operating conditions
architecture
standard planetary
nut type
double
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating basis
rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit
Source evidence
RV 12 x 8 (5 starts) | Dynamic load capacity Ca: 18,6 kN | {'nut_type': 'double', 'rating_basis': 'rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit'}

PDF p.26 / RV 12 x 8 (5 starts) / Dynamic load capacity Ca

Source observed: 2026-09-14View source
Dynamic axial load capacity CaModel-level statement18,6 kN

rule validated

Operating conditions
architecture
standard planetary
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating basis
rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit
Source evidence
RV 12 x 8 (5 starts) | Dynamic load capacity Ca: 18,6 kN | {'nut_type': 'single', 'rating_basis': 'rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit'}

PDF p.26 / RV 12 x 8 (5 starts) / Dynamic load capacity Ca

Source observed: 2026-09-14View source
Dynamic axial load capacity CaModel-level statement10,2 kN

rule validated

Operating conditions
architecture
standard planetary
nut type
split
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating basis
rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit
Source evidence
RV 12 x 8 (5 starts) | Dynamic load capacity Ca: 10,2 kN | {'nut_type': 'split', 'rating_basis': 'rolling fatigue; use catalog load/life and preload equations, not a continuous thrust limit'}

PDF p.26 / RV 12 x 8 (5 starts) / Dynamic load capacity Ca

Source observed: 2026-09-14View source
Indirect efficiencyModel-level statement0,83 1

rule validated

Operating conditions
architecture
standard planetary
direction
linear to rotary
ordering scope
published diameter/lead/start configuration; not a complete ordering code
rating note
catalog estimate; not proof of system backdrivability
Source evidence
RV 12 x 8 (5 starts) | Indirect efficiency: 0,83 1 | {'direction': 'linear to rotary', 'rating_note': 'catalog estimate; not proof of system backdrivability'}

PDF p.26 / RV 12 x 8 (5 starts) / Indirect efficiency

Source observed: 2026-09-14View source
Lead (travel per revolution)Model-level statement8 mm/rev

rule validated

Operating conditions
architecture
standard planetary
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Lead P (travel per revolution): 8 mm/rev | {}

PDF p.26 / RV 12 x 8 (5 starts) / Lead P (travel per revolution)

Source observed: 2026-09-14View source
Preloading force FvModel-level statement146 N

rule validated

Operating conditions
architecture
standard planetary
nut type
double
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Preloading force Fv: 146 N | {'nut_type': 'double'}

PDF p.26 / RV 12 x 8 (5 starts) / Preloading force Fv

Source observed: 2026-09-14View source
Preloading force FvModel-level statement146 N

rule validated

Operating conditions
architecture
standard planetary
nut type
split
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Preloading force Fv: 146 N | {'nut_type': 'split'}

PDF p.26 / RV 12 x 8 (5 starts) / Preloading force Fv

Source observed: 2026-09-14View source
Preload torque MvModel-level statement0,08 N·m

rule validated

Operating conditions
architecture
standard planetary
nut type
split
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Preload torque Mv: 0,08 N·m | {'nut_type': 'split'}

PDF p.26 / RV 12 x 8 (5 starts) / Preload torque Mv

Source observed: 2026-09-14View source
Preload torque MvModel-level statement0,08 N·m

rule validated

Operating conditions
architecture
standard planetary
nut type
double
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Preload torque Mv: 0,08 N·m | {'nut_type': 'double'}

PDF p.26 / RV 12 x 8 (5 starts) / Preload torque Mv

Source observed: 2026-09-14View source
Screw reference diameter DModel-level statement12 mm

rule validated

Operating conditions
architecture
standard planetary
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Reference diameter D: 12 mm | {}

PDF p.26 / RV 12 x 8 (5 starts) / Reference diameter D

Source observed: 2026-09-14View source
Rigidity factor FkModel-level statement33,1 N^(2/3)/µm

rule validated

Operating conditions
architecture
standard planetary
definition
nonlinear rigidity factor, not assembled axial stiffness
nut type
double
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Rigidity factor Fk: 33,1 N^(2/3)/µm | {'nut_type': 'double', 'definition': 'nonlinear rigidity factor, not assembled axial stiffness'}

PDF p.26 / RV 12 x 8 (5 starts) / Rigidity factor Fk

Source observed: 2026-09-14View source
Rigidity factor FkModel-level statement13,9 N^(2/3)/µm

rule validated

Operating conditions
architecture
standard planetary
definition
nonlinear rigidity factor, not assembled axial stiffness
nut type
split
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Rigidity factor Fk: 13,9 N^(2/3)/µm | {'nut_type': 'split', 'definition': 'nonlinear rigidity factor, not assembled axial stiffness'}

PDF p.26 / RV 12 x 8 (5 starts) / Rigidity factor Fk

Source observed: 2026-09-14View source
Rigidity factor FkModel-level statement22,0 N^(2/3)/µm

rule validated

Operating conditions
architecture
standard planetary
definition
nonlinear rigidity factor, not assembled axial stiffness
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Rigidity factor Fk: 22,0 N^(2/3)/µm | {'nut_type': 'single', 'definition': 'nonlinear rigidity factor, not assembled axial stiffness'}

PDF p.26 / RV 12 x 8 (5 starts) / Rigidity factor Fk

Source observed: 2026-09-14View source
Static axial load capacity C0aModel-level statement12,5 kN

rule validated

Operating conditions
architecture
standard planetary
nut type
split
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Static load capacity C0a: 12,5 kN | {'nut_type': 'split'}

PDF p.26 / RV 12 x 8 (5 starts) / Static load capacity C0a

Source observed: 2026-09-14View source
Static axial load capacity C0aModel-level statement24,9 kN

rule validated

Operating conditions
architecture
standard planetary
nut type
double
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Static load capacity C0a: 24,9 kN | {'nut_type': 'double'}

PDF p.26 / RV 12 x 8 (5 starts) / Static load capacity C0a

Source observed: 2026-09-14View source
Static axial load capacity C0aModel-level statement24,9 kN

rule validated

Operating conditions
architecture
standard planetary
nut type
single
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Static load capacity C0a: 24,9 kN | {'nut_type': 'single'}

PDF p.26 / RV 12 x 8 (5 starts) / Static load capacity C0a

Source observed: 2026-09-14View source
Thread startsModel-level statement5 1

rule validated

Operating conditions
architecture
standard planetary
ordering scope
published diameter/lead/start configuration; not a complete ordering code
Source evidence
RV 12 x 8 (5 starts) | Number of starts N: 5 1 | {}

PDF p.26 / RV 12 x 8 (5 starts) / Number of starts N

Source observed: 2026-09-14View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error