PartMeld

RLS

MB053 shape E + MRA053BC030DSE00 (configurable assembly)

Model / article: MB053 shape E + MRA053BC030DSE00 (configurable assembly)

MB053 shape E + MRA053BC030DSE00 (configurable assembly) is listed by RLS in Absolute encoders. Published model data includes Angular accuracy: 0.006 °; Single-turn resolution: 20 bit (maximum). See the specification table for operating conditions and source evidence.

Manufacturer-published readhead/ring assembly configurations, not complete ordering codes. Select interface, resolution and connector separately. No functional-safety certification verified.

Family image
Family image

Product overview

Manufacturer / supplier
RLS
Series
AksIM-2 MB053 shape E assembly with MRA053BC030DSE00
Component type
Absolute encoders
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for MB053 shape E + MRA053BC030DSE00 (configurable assembly)
SpecificationPublished valueConditions and source
Angular accuracyModel-level statement0.006 °

rule validated

Operating conditions
basis
two readheads or best possible after self-calibration
bound
± angular error
Source evidence
System accuracy: 0.006

MBD01_15 p.4 / MB053 / System accuracy

Source observed: 2026-09-18View source
Angular accuracyModel-level statement0.04 °Rating: typical

rule validated

Operating conditions
basis
typical installed without calibration; mounting eccentricity and bearing wander affect accuracy
bound
± angular error
Source evidence
Installed accuracy uncalibrated: 0.04

MBD01_15 p.4 / MB053 / Installed accuracy uncalibrated

Source observed: 2026-09-18View source
Angular accuracyModel-level statement0.012 °Rating: typical

rule validated

Operating conditions
basis
typical installed after calibration
bound
± angular error
Source evidence
Installed accuracy calibrated: 0.012

MBD01_15 p.4 / MB053 / Installed accuracy calibrated

Source observed: 2026-09-18View source
Multi-turn counter after power lossModel-level statementCounts only when powered; retains counter at power-down. Unpowered full rotations are not registered. User must validate counter or constrain motion.

rule validated

Operating conditions
maximum power down rotation
±90°; full turns can remain undetected
scope
optional 16-bit multiturn counter, not standard on every configuration
Source evidence
Optional multiturn counter limitations: Counts only when powered; retains counter at power-down. Unpowered full rotations are not registered. User must validate counter or constrain motion.

MBD01_15 p.30 / MB053 / Optional multiturn counter limitations

Source observed: 2026-09-18View source
Communication interfaceModel-level statementBiSS, UART, SPI, PWM, SSI (SSI not recommended for new design)

rule validated

Operating conditions
scope
options; select valid combination from manufacturer table
Source evidence
Available communication interfaces: BiSS, UART, SPI, PWM, SSI (SSI not recommended for new design)

MBD01_15 p.47 / MB053 / Available communication interfaces

Source observed: 2026-09-18View source
Single-turn resolutionModel-level statement20 bitRating: maximum

rule validated

Operating conditions
noise
high-resolution options may contain noise; influenced by ride height
scope
maximum available option, not a fixed ordered configuration
Source evidence
Maximum configurable resolution: 20

MBD01_15 p.4 / MB053 / Maximum configurable resolution

Source observed: 2026-09-18View source
Start-up timeModel-level statement200 msRating: maximum

rule validated

Operating conditions
basis
after supply voltage enters range
usual ms
100
Source evidence
Worst-case first-data setup time: 200

MBD01_15 p.4 / MB053 / Worst-case first-data setup time

Source observed: 2026-09-18View source
Supply currentModel-level statement150 mARating: maximum

rule validated

Operating conditions
outputs
unloaded
typical ma
130
Source evidence
Maximum supply current: 150

MBD01_15 p.4 / MB053 / Maximum supply current

Source observed: 2026-09-18View source
Supply voltage rangeModel-level statement4.5–5.5 V at connector V

rule validated

Operating conditions
rise time
less than 20 ms
Source evidence
Supply voltage: 4.5–5.5 V at connector

MBD01_15 p.4 / MB053 / Supply voltage

Source observed: 2026-09-18View source
Operating temperatureModel-level statement-40 to 105 °C °C

rule validated

Source evidence
Operating temperature: -40 to 105 °C

MBD01_15 p.5 / MB053 / Operating temperature

Source observed: 2026-09-18View source
Measurement typeModel-level statementConfigurable assembly; interface, resolution and counter options must be specified

rule validated

Source evidence
Configuration scope: Configurable assembly; interface, resolution and counter options must be specified

MBD01_15 p.47 / MB053 / Configuration scope

Source observed: 2026-09-18View source
Encoder typeModel-level statementOff-axis absolute magnetic, axial reading

rule validated

Source evidence
Reading technology: Off-axis absolute magnetic, axial reading

MBD01_15 p.4 / MB053 / Reading technology

Source observed: 2026-09-18View source
Maximum output speedModel-level statement7500 rpmRating: maximum

rule validated

Source evidence
Maximum speed: 7500

MBD01_15 p.4 / MB053 / Maximum speed

Source observed: 2026-09-18View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error