PartMeld

AGS Automation Greifsysteme Schwope GmbH

SG1-51-S-FDA-50-U-14

Model / article: 1-57-24-28-00-SG1

SG1-51-S-FDA-50-U-14 is listed by AGS Automation Greifsysteme Schwope GmbH in Vacuum end effectors. Published model data includes Product mass: 0.005Kg. See the specification table for operating conditions and source evidence.

55.0 Vacuum Cups - Complete. SG1-S-FDA-U Vacuum Cup 1 Bellow (complete) Silicone FDA universal. Listed in the manufacturer-supplied PRECIGRIP catalogue dated 30 October 2026. Prices, availability and CAD are available on request from AGS; no downloadable CAD or stock status is inferred.

Catalogue range illustration (not a variant-specific photograph)
Catalogue range illustration (not a variant-specific photograph)

Product overview

Manufacturer / supplier
AGS Automation Greifsysteme Schwope GmbH
Series
SG1-S-FDA-U Vacuum Cup 1 Bellow (complete) Silicone FDA universal
Component type
Vacuum end effectors
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for SG1-51-S-FDA-50-U-14
SpecificationPublished valueConditions and source
Catalogue legendModel-level statementLegend: J = Suction pad colour K = Bellows hardness °Shore A L = Suction pad stroke M = Horizontal holding force at vacuum -0.6 bar N = Holding force vertical at vacuum -0.6 bar Holding force 10N = 1kg O = Material

rule validated

Operating conditions
basis
Printed catalogue value; drawing letters and family-specific conditions retained. Dimensions in mm unless otherwise stated. No force-to-payload conversion.
catalogue page
126
table
2
Source evidence
Legend: J = Suction pad colour K = Bellows hardness °Shore A L = Suction pad stroke M = Horizontal holding force at vacuum -0.6 bar N = Holding force vertical at vacuum -0.6 bar Holding force 10N = 1kg O = Material

PRECIGRIP catalogue 30 Oct 2026 / PDF page 126 / table on page 126, table 2 / 1-57-24-28-00-SG1 / Drawing and table legend

Source observed: 2026-11-02View source
Catalogue notesModel-level statementSG1-S-FDA-U Vacuum Cup 1 Bellow (complete) Silicone FDA universal ADVANTAGES V1 - The material used is food-safe silicone. It is free from colour pigments and approved by the FDA (FDA 21 CFR 177.2600.) and fulfils the EU regulation EU 935/2004.(FDA approved) V2 - soft and flexible (without support ribs) V3 - wide temperature application range V4 - Availability from very small sizes V5 - Adapter has integrated filter screen (except M5) V6 - universal use INFO Material: S-FDA univ. silicone FDA approved Shore hardness: 50°Shore A suction cup transparent Temperature resistance: -40°C to +200°C Flexibility: *** Wear resistance: *** Resistance to oil: - Compatibility with foodstuffs: *** Area of application: Suitable for flat or slightly curved surfaces Also suitable for concave workpieces Used in the food industry and in the pharmaceutical industry Silicone material fulfils FDA 21 CFR 177.2600

rule validated

Operating conditions
basis
Printed catalogue value; drawing letters and family-specific conditions retained. Dimensions in mm unless otherwise stated. No force-to-payload conversion.
catalogue page
126
table
2
Source evidence
SG1-S-FDA-U Vacuum Cup 1 Bellow (complete) Silicone FDA universal ADVANTAGES V1 - The material used is food-safe silicone. It is free from colour pigments and approved by the FDA (FDA 21 CFR 177.2600.) and fulfils the EU regulation EU 935/2004.(FDA approved) V2 - soft and flexible (without support ribs) V3 - wide temperature application range V4 - Availability from very small sizes V5 - Adapter has integrated filter screen (except M5) V6 - universal use INFO Material: S-FDA univ. silicone FDA approved Shore hardness: 50°Shore A suction cup transparent Temperature resistance: -40°C to +200°C Fl

PRECIGRIP catalogue 30 Oct 2026 / PDF page 126 / table on page 126, table 2 / 1-57-24-28-00-SG1 / Catalogue description and operating notes

Source observed: 2026-11-02View source
Catalogue specificationsModel-level statementA: 51,40; B: 23,50; C: G1/4; J: transp.; K: 50; L: 6; M: 37N; N: 73N; O: S-FDA; WEIGHT: 0.005Kg

rule validated

Operating conditions
basis
Printed catalogue value; drawing letters and family-specific conditions retained. Dimensions in mm unless otherwise stated. No force-to-payload conversion.
catalogue page
126
table
2
Source evidence
A: 51,40; B: 23,50; C: G1/4; J: transp.; K: 50; L: 6; M: 37N; N: 73N; O: S-FDA; WEIGHT: 0.005Kg

PRECIGRIP catalogue 30 Oct 2026 / PDF page 126 / table on page 126, table 2 / 1-57-24-28-00-SG1 / Catalogue specifications

Source observed: 2026-11-02View source
Product massModel-level statement0.005Kg

rule validated

Operating conditions
basis
Printed catalogue value; drawing letters and family-specific conditions retained. Dimensions in mm unless otherwise stated. No force-to-payload conversion.
catalogue page
126
table
2
Source evidence
0.005Kg

PRECIGRIP catalogue 30 Oct 2026 / PDF page 126 / table on page 126, table 2 / 1-57-24-28-00-SG1 / Catalogue weight

Source observed: 2026-11-02View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error