RD4221-C2
Model / article: RD4221-C2
RD4221-C2 is listed by Micropower in Robot charging systems. Published model data includes Product mass: 2 kg; Dimensions: 122 x 73 x 278 mm. See the specification table for operating conditions and source evidence.
Micropower RC onboard charger for configured lead-acid/lithium-ion charging. Exact suffix and technical sheet retained. Model-level thermal and input ratings take precedence over broad family brochure values. Full-power input dependence and complete charging-voltage curve remain unnormalized. Compliance marks are manufacturer-reported; no robot functional-safety certification or fleet/cloud features inferred.

Product overview
- Manufacturer / supplier
- Micropower
- Series
- RD4221-C2 onboard charger
- Component type
- Robot charging systems
- Source
- Open published source
Published pricing
No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.
Published specifications
Values are shown as published. Conditions, rating basis and source evidence apply to each value.
Latest source observation: . Observation dates record evidence collection, not supplier re-verification.
| Specification | Published value | Conditions and source |
|---|---|---|
| Charger ac inputModel-level statement | 100 to 240 V | rule validated Operating conditions
Source evidenceRated AC input voltage: 100 to 240 V RD4221-C2 / model technical sheet / PDF p.1 / Rated AC input voltage |
| Charger apparent powerModel-level statement | 1105.0 VA | rule validated Operating conditions
Source evidenceApparent input power: 1105.0 VA RD4221-C2 / model technical sheet / PDF p.1 / Apparent input power |
| Charger chemistriesModel-level statement | Multiple Lead/LiIon/CAN | rule validated Operating conditions
Source evidenceCharging curve set: Multiple Lead/LiIon/CAN RD4221-C2 / model technical sheet / PDF p.2 / Charging curve set |
| Charger component roleModel-level statement | Onboard AC battery charger | rule validated Source evidenceComponent role: Onboard AC battery charger RD4221-C2 / model technical sheet / PDF p.1 / Component role |
| Charger coolingModel-level statement | Convection | rule validated Source evidenceCooling: Convection RD4221-C2 / model technical sheet / PDF p.2 / Cooling |
| Charger currentModel-level statement | 18.0 A | rule validated Operating conditions
Source evidenceOutput current rating: 18.0 A RD4221-C2 / model technical sheet / PDF p.2 / Output current rating |
| Charger efficiencyModel-level statement | 96.0 % | rule validated Operating conditions
Source evidenceEfficiency: 96.0 % RD4221-C2 / model technical sheet / PDF p.1 / Efficiency |
| Charger environmentModel-level statement | Altitude ≤2000 m; non-condensing humidity ≤95% | rule validated Source evidenceEnvironmental limits: Altitude ≤2000 m; non-condensing humidity ≤95% RD4221-C2 / model technical sheet / PDF p.2 / Environmental limits |
| Charger input currentModel-level statement | 7,0/4,8 A | rule validated Operating conditions
Source evidenceInput current at nominal mains: 7,0/4,8 A RD4221-C2 / model technical sheet / PDF p.1 / Input current at nominal mains |
| Charger input frequencyModel-level statement | 50 to 60 Hz | rule validated Source evidenceInput frequency: 50 to 60 Hz RD4221-C2 / model technical sheet / PDF p.1 / Input frequency |
| Charger input powerModel-level statement | 1083.0 W | rule validated Operating conditions
Source evidenceInput power consumption: 1083.0 W RD4221-C2 / model technical sheet / PDF p.1 / Input power consumption |
| Charger listed marksModel-level statement | CE/UL | rule validated Operating conditions
Source evidenceManufacturer-listed compliance marks: CE/UL RD4221-C2 / model technical sheet / PDF p.2 / Manufacturer-listed compliance marks |
| Charger model codeModel-level statement | 2A1F930 | rule validated Source evidenceManufacturer model code: 2A1F930 RD4221-C2 / model technical sheet / PDF p.1 / Manufacturer model code |
| Charger nominal battery voltageModel-level statement | 48.0 V | rule validated Operating conditions
Source evidenceNominal DC battery rating: 48.0 V RD4221-C2 / model technical sheet / PDF p.2 / Nominal DC battery rating |
| Charger output fuseModel-level statement | 60 A / 72 VDC, non-replaceable, medium acting | rule validated Operating conditions
Source evidenceOutput fuse: 60 A / 72 VDC, non-replaceable, medium acting RD4221-C2 / model technical sheet / PDF p.2 / Output fuse |
| Charger output terminalsModel-level statement | M6 & M8 | rule validated Source evidenceOutput cable terminals in unit: M6 & M8 RD4221-C2 / model technical sheet / PDF p.2 / Output cable terminals in unit |
| Charger receptacleModel-level statement | IEC 60320 Type C16, IP67 | rule validated Source evidenceTypical supply inlet: IEC 60320 Type C16, IP67 RD4221-C2 / model technical sheet / PDF p.1 / Typical supply inlet |
| Charger storage limitsModel-level statement | -40 to +85°C / 1000 h | rule validated Operating conditions
Source evidenceStorage and transport limits: -40 to +85°C / 1000 h RD4221-C2 / model technical sheet / PDF p.2 / Storage and transport limits |
| DimensionsModel-level statement | 122 x 73 x 278 mm | rule validated Operating conditions
Source evidenceCharger dimensions: 122 x 73 x 278 mm RD4221-C2 / model technical sheet / PDF p.2 / Charger dimensions |
| Ingress protection ratingModel-level statement | IP67 | rule validated Operating conditions
Source evidenceIngress protection: IP67 RD4221-C2 / model technical sheet / PDF p.2 / Ingress protection |
| Product massModel-level statement | 2 kg | rule validated Operating conditions
Source evidenceWeight excluding cables: 2 kg RD4221-C2 / model technical sheet / PDF p.2 / Weight excluding cables |
| Operating temperature rangeModel-level statement | -35 to 40 °C | rule validated Operating conditions
Source evidenceOperating ambient temperature: -35 to 40 °C RD4221-C2 / model technical sheet / PDF p.2 / Operating ambient temperature |
Technical documents and resources
Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.