| Depth resolutionModel-level statement | 3.2 Mpix (2064 x 1544) | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Depth map resolution: 3.2 Mpix (2064 x 1544) #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| DimensionsModel-level statement | 628 x 68 x 86 mm | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Dimensions: 628 x 68 x 86 mm #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Product massModel-level statement | 1100g | rule validated Operating conditions- definition
- Without accessories
- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Weight: 1100g #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Nominal supply voltageModel-level statement | PoE or 24V | rule validated Operating conditions- alternative supply
- Power over Ethernet
- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Power: PoE or 24V #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Operating temperature rangeModel-level statement | Full: 0 - 40 °C (32 - 104 °F) Optimal: 22 - 25 °C (71.6 - 77 °F) | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- optimal temperature C
- [22,25]
- thermalization
- Required for optimum performance
Source evidencePhoXi 3D Scanner L Gen2 | Temperature working range: Full: 0 - 40 °C (32 - 104 °F) Optimal: 22 - 25 °C (71.6 - 77 °F) #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Sensor interfaceModel-level statement | 1 Gbit Ethernet | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Data connection: 1 Gbit Ethernet #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision acquisition timeModel-level statement | From 190 msRating: minimum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Acquisition time: From 190 ms #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision baselineModel-level statement | 550.0 mm | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Baseline: 550.0 mm #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision global planarityModel-level statement | 1.25Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- far
- scanning distance mm
- 2150
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Global planarity (mm): 1.25 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision global planarityModel-level statement | 0.40Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- near
- scanning distance mm
- 870
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Global planarity (mm): 0.40 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision global planarityModel-level statement | 0.65Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- sweet
- scanning distance mm
- 1244
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Global planarity (mm): 0.65 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision ingress protectionModel-level statement | IP65 | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | IP rating: IP65 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision laser colorModel-level statement | Red | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Projection unit laser color: Red #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision local planarityModel-level statement | 0.25Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- sweet
- scanning distance mm
- 1244
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Local planarity (mm): 0.25 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision local planarityModel-level statement | 0.50Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- far
- scanning distance mm
- 2150
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Local planarity (mm): 0.50 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision local planarityModel-level statement | 0.15Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- near
- scanning distance mm
- 870
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Local planarity (mm): 0.15 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision output dataModel-level statement | 3D points (x y z), Normals (x y z), Depth Map (z), Texture (grayscale intensity), Confidence | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Output data: 3D points (x y z), Normals (x y z), Depth Map (z), Texture (grayscale intensity), Confidence #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision point spacingModel-level statement | 0.92Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- far
- scanning distance mm
- 2150
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Point-to-point distance (mm): 0.92 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision point spacingModel-level statement | 0.37Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- near
- scanning distance mm
- 870
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Point-to-point distance (mm): 0.37 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision point spacingModel-level statement | 0.53Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- sweet
- scanning distance mm
- 1244
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Point-to-point distance (mm): 0.53 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision processorModel-level statement | NVIDIA Jetson TX2 | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Processing unit: NVIDIA Jetson TX2 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision relative distance accuracyModel-level statement | 1.25Rating: maximum | rule validated Operating conditions- definition
- 68th percentile of measured relative errors; marker-based maintenance. Autonomous-only maintenance may add up to 0.2%; each 10°C deviation may add up to 0.15%.
- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- sweet
- scanning distance mm
- 1244
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Relative distance accuracy (‰): 1.25 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision relative distance accuracyModel-level statement | 1.25Rating: maximum | rule validated Operating conditions- definition
- 68th percentile of measured relative errors; marker-based maintenance. Autonomous-only maintenance may add up to 0.2%; each 10°C deviation may add up to 0.15%.
- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- far
- scanning distance mm
- 2150
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Relative distance accuracy (‰): 1.25 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision relative distance accuracyModel-level statement | 1.25Rating: maximum | rule validated Operating conditions- definition
- 68th percentile of measured relative errors; marker-based maintenance. Autonomous-only maintenance may add up to 0.2%; each 10°C deviation may add up to 0.15%.
- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- near
- scanning distance mm
- 870
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Relative distance accuracy (‰): 1.25 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision scan areaModel-level statement | 1117 x 797 mm | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- scanning distance mm
- 1244
Source evidencePhoXi 3D Scanner L Gen2 | Scanning area (sweet spot): 1117 x 797 mm #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision scanning timeModel-level statement | From 250msRating: minimum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | Scanning time: From 250ms #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision system typeModel-level statement | Structured Light | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidencePhoXi 3D Scanner L Gen2 | 3D sensing technology: Structured Light #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision temporal noiseModel-level statement | 0.02Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- near
- scanning distance mm
- 870
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Temporal noise (mm): 0.02 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision temporal noiseModel-level statement | 0.05Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- sweet
- scanning distance mm
- 1244
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Temporal noise (mm): 0.05 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Vision temporal noiseModel-level statement | 0.13Rating: maximum | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- position
- far
- scanning distance mm
- 2150
- standard conditions
- Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidencePhoXi 3D Scanner L Gen2 | Temporal noise (mm): 0.13 #panel-11-11-3 Source observed: 2026-10-13View source |
|---|
| Working distanceModel-level statement | 870 - 1244 - 2150 mm | rule validated Operating conditions- hardware revision scope
- Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
- sweet spot mm
- 1244
Source evidencePhoXi 3D Scanner L Gen2 | Scanning range (near - sweet - far): 870 - 1244 - 2150 mm #panel-11-11-3 Source observed: 2026-10-13View source |
|---|