PartMeld

Photoneo

PhoXi 3D Scanner L Gen2

Model / article: PhoXi 3D Scanner L Gen2

PhoXi 3D Scanner L Gen2 is listed by Photoneo in 3D robot cameras. Published model data includes Product mass: 1100g; Dimensions: 628 x 68 x 86 mm. See the specification table for operating conditions and source evidence.

PhoXi 3D Scanner Gen2

Manufacturer Gen2 family illustration; depicts M size, not exact dimensions of other sizes.
Manufacturer Gen2 family illustration; depicts M size, not exact dimensions of other sizes.

Product overview

Manufacturer / supplier
Photoneo
Series
PhoXi 3D Scanner Gen2
Component type
3D robot cameras
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for PhoXi 3D Scanner L Gen2
SpecificationPublished valueConditions and source
Depth resolutionModel-level statement3.2 Mpix (2064 x 1544)

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Depth map resolution: 3.2 Mpix (2064 x 1544)

#panel-11-11-3

Source observed: 2026-10-13View source
DimensionsModel-level statement628 x 68 x 86 mm

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Dimensions: 628 x 68 x 86 mm

#panel-11-11-3

Source observed: 2026-10-13View source
Product massModel-level statement1100g

rule validated

Operating conditions
definition
Without accessories
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Weight: 1100g

#panel-11-11-3

Source observed: 2026-10-13View source
Nominal supply voltageModel-level statementPoE or 24V

rule validated

Operating conditions
alternative supply
Power over Ethernet
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Power: PoE or 24V

#panel-11-11-3

Source observed: 2026-10-13View source
Operating temperature rangeModel-level statementFull: 0 - 40 °C (32 - 104 °F) Optimal: 22 - 25 °C (71.6 - 77 °F)

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
optimal temperature C
[22,25]
thermalization
Required for optimum performance
Source evidence
PhoXi 3D Scanner L Gen2 | Temperature working range: Full: 0 - 40 °C (32 - 104 °F) Optimal: 22 - 25 °C (71.6 - 77 °F)

#panel-11-11-3

Source observed: 2026-10-13View source
Sensor interfaceModel-level statement1 Gbit Ethernet

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Data connection: 1 Gbit Ethernet

#panel-11-11-3

Source observed: 2026-10-13View source
Vision acquisition timeModel-level statementFrom 190 msRating: minimum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Acquisition time: From 190 ms

#panel-11-11-3

Source observed: 2026-10-13View source
Vision baselineModel-level statement550.0 mm

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Baseline: 550.0 mm

#panel-11-11-3

Source observed: 2026-10-13View source
Vision global planarityModel-level statement1.25Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
far
scanning distance mm
2150
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Global planarity (mm): 1.25

#panel-11-11-3

Source observed: 2026-10-13View source
Vision global planarityModel-level statement0.40Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
near
scanning distance mm
870
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Global planarity (mm): 0.40

#panel-11-11-3

Source observed: 2026-10-13View source
Vision global planarityModel-level statement0.65Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
sweet
scanning distance mm
1244
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Global planarity (mm): 0.65

#panel-11-11-3

Source observed: 2026-10-13View source
Vision ingress protectionModel-level statementIP65

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | IP rating: IP65

#panel-11-11-3

Source observed: 2026-10-13View source
Vision laser colorModel-level statementRed

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Projection unit laser color: Red

#panel-11-11-3

Source observed: 2026-10-13View source
Vision local planarityModel-level statement0.25Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
sweet
scanning distance mm
1244
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Local planarity (mm): 0.25

#panel-11-11-3

Source observed: 2026-10-13View source
Vision local planarityModel-level statement0.50Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
far
scanning distance mm
2150
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Local planarity (mm): 0.50

#panel-11-11-3

Source observed: 2026-10-13View source
Vision local planarityModel-level statement0.15Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
near
scanning distance mm
870
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Local planarity (mm): 0.15

#panel-11-11-3

Source observed: 2026-10-13View source
Vision output dataModel-level statement3D points (x y z), Normals (x y z), Depth Map (z), Texture (grayscale intensity), Confidence

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Output data: 3D points (x y z), Normals (x y z), Depth Map (z), Texture (grayscale intensity), Confidence

#panel-11-11-3

Source observed: 2026-10-13View source
Vision point spacingModel-level statement0.92Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
far
scanning distance mm
2150
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Point-to-point distance (mm): 0.92

#panel-11-11-3

Source observed: 2026-10-13View source
Vision point spacingModel-level statement0.37Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
near
scanning distance mm
870
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Point-to-point distance (mm): 0.37

#panel-11-11-3

Source observed: 2026-10-13View source
Vision point spacingModel-level statement0.53Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
sweet
scanning distance mm
1244
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Point-to-point distance (mm): 0.53

#panel-11-11-3

Source observed: 2026-10-13View source
Vision processorModel-level statementNVIDIA Jetson TX2

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Processing unit: NVIDIA Jetson TX2

#panel-11-11-3

Source observed: 2026-10-13View source
Vision relative distance accuracyModel-level statement1.25Rating: maximum

rule validated

Operating conditions
definition
68th percentile of measured relative errors; marker-based maintenance. Autonomous-only maintenance may add up to 0.2%; each 10°C deviation may add up to 0.15%.
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
sweet
scanning distance mm
1244
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Relative distance accuracy (‰): 1.25

#panel-11-11-3

Source observed: 2026-10-13View source
Vision relative distance accuracyModel-level statement1.25Rating: maximum

rule validated

Operating conditions
definition
68th percentile of measured relative errors; marker-based maintenance. Autonomous-only maintenance may add up to 0.2%; each 10°C deviation may add up to 0.15%.
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
far
scanning distance mm
2150
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Relative distance accuracy (‰): 1.25

#panel-11-11-3

Source observed: 2026-10-13View source
Vision relative distance accuracyModel-level statement1.25Rating: maximum

rule validated

Operating conditions
definition
68th percentile of measured relative errors; marker-based maintenance. Autonomous-only maintenance may add up to 0.2%; each 10°C deviation may add up to 0.15%.
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
near
scanning distance mm
870
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Relative distance accuracy (‰): 1.25

#panel-11-11-3

Source observed: 2026-10-13View source
Vision scan areaModel-level statement1117 x 797 mm

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
scanning distance mm
1244
Source evidence
PhoXi 3D Scanner L Gen2 | Scanning area (sweet spot): 1117 x 797 mm

#panel-11-11-3

Source observed: 2026-10-13View source
Vision scanning timeModel-level statementFrom 250msRating: minimum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | Scanning time: From 250ms

#panel-11-11-3

Source observed: 2026-10-13View source
Vision system typeModel-level statementStructured Light

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
Source evidence
PhoXi 3D Scanner L Gen2 | 3D sensing technology: Structured Light

#panel-11-11-3

Source observed: 2026-10-13View source
Vision temporal noiseModel-level statement0.02Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
near
scanning distance mm
870
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Temporal noise (mm): 0.02

#panel-11-11-3

Source observed: 2026-10-13View source
Vision temporal noiseModel-level statement0.05Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
sweet
scanning distance mm
1244
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Temporal noise (mm): 0.05

#panel-11-11-3

Source observed: 2026-10-13View source
Vision temporal noiseModel-level statement0.13Rating: maximum

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
position
far
scanning distance mm
2150
standard conditions
Homogeneous ambient light without strong/flashing sources; stable humidity and room temperature (ISO 554); no shock or shaking. Properly maintained device. Table performance values are maxima, not typical graph values.
Source evidence
PhoXi 3D Scanner L Gen2 | Temporal noise (mm): 0.13

#panel-11-11-3

Source observed: 2026-10-13View source
Working distanceModel-level statement870 - 1244 - 2150 mm

rule validated

Operating conditions
hardware revision scope
Devices produced after May 2025; corroborated by 01-2026-v1.1 PDF
sweet spot mm
1244
Source evidence
PhoXi 3D Scanner L Gen2 | Scanning range (near - sweet - far): 870 - 1244 - 2150 mm

#panel-11-11-3

Source observed: 2026-10-13View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error