PartMeld

SLAMTEC

RPLIDAR S2E

Model / article: S2E

RPLIDAR S2E is listed by SLAMTEC in Robot LiDAR. Published model data includes Nominal supply voltage: 12V; Operating temperature range: -10℃-50℃. See the specification table for operating conditions and source evidence.

Published S2 product models; pitch-angle ordering-code variants are not separately indexed.

Manufacturer S2E exterior illustration
Manufacturer S2E exterior illustration

Product overview

Manufacturer / supplier
SLAMTEC
Series
RPLIDAR S2
Component type
Robot LiDAR
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for RPLIDAR S2E
SpecificationPublished valueConditions and source
Lidar angular resolutionModel-level statement0.1125°Rating: typical

rule validated

Operating conditions
qualifier source
Overview table explicitly labels rotational speed and angular resolution typical
Source evidence
S2E | Angular Resolution: 0.1125°

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar blind rangeModel-level statement0.05m

rule validated

Source evidence
S2E | Blind Range: 0.05m

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar distance accuracyModel-level statement±30mm

rule validated

Operating conditions
sign
± magnitude; not a 1-sigma statistical measure
Source evidence
S2E | Accuracy: ±30mm

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar distance resolutionModel-level statement13mm

rule validated

Source evidence
S2E | Distance Resolution: 13mm

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar frame rateModel-level statement10HzRating: typical

rule validated

Operating conditions
qualifier source
Overview table explicitly labels rotational speed and angular resolution typical
Source evidence
S2E | Scan Rate: 10Hz

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar point rateModel-level statement32000 times per secord

rule validated

Source evidence
S2E | Sample Rate: 32000 times per secord

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar powerModel-level statement> 2W

rule validated

Operating conditions
comparison
Unnormalized lower-bound statement; not maximum consumption
Source evidence
S2E | Power Consumption: > 2W

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar range 10 reflectivityModel-level statement0.05-10m(10% reflection)Rating: maximum

rule validated

Operating conditions
minimum distance m
0.05
target reflectivity percent
10
Source evidence
S2E | Distance Range: 0.05-10m(10% reflection)

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar range 90 reflectivityModel-level statement0.05-30m(90% reflection)Rating: maximum

rule validated

Operating conditions
minimum distance m
0.05
target reflectivity percent
90
Source evidence
S2E | Distance Range: 0.05-30m(90% reflection)

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Lidar scan flatnessModel-level statement±1.5°

rule validated

Operating conditions
sign
± magnitude; not a 1-sigma statistical measure
Source evidence
S2E | Scan Field Flatness: ±1.5°

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Nominal supply voltageModel-level statement12V

rule validated

Source evidence
S2E | System Voltage: 12V

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Operating temperature rangeModel-level statement-10℃-50℃

rule validated

Source evidence
S2E | Temperature Range: -10℃-50℃

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Sensor interfaceModel-level statementEthernet UDP(10/100M)

rule validated

Source evidence
S2E | Communication Interface: Ethernet UDP(10/100M)

table.a3-parameter-table column 4

Source observed: 2026-10-13View source
Vision ingress protectionModel-level statementIP65

rule validated

Source evidence
S2E | Proof Level: IP65

table.a3-parameter-table column 4

Source observed: 2026-10-13View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error