PartMeld

SLAMTEC

RPLIDAR S2

Model / article: S2

RPLIDAR S2 is listed by SLAMTEC in Robot LiDAR. Published model data includes Nominal supply voltage: 5V; Operating temperature range: -10℃-50℃. See the specification table for operating conditions and source evidence.

Published S2 product models; pitch-angle ordering-code variants are not separately indexed.

Manufacturer shared S2L/S2/S2P exterior illustration
Manufacturer shared S2L/S2/S2P exterior illustration

Product overview

Manufacturer / supplier
SLAMTEC
Series
RPLIDAR S2
Component type
Robot LiDAR
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for RPLIDAR S2
SpecificationPublished valueConditions and source
Lidar angular resolutionModel-level statement0.1125°Rating: typical

rule validated

Operating conditions
qualifier source
Overview table explicitly labels rotational speed and angular resolution typical
Source evidence
S2 | Angular Resolution: 0.1125°

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar blind rangeModel-level statement0.05m

rule validated

Source evidence
S2 | Blind Range: 0.05m

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar distance accuracyModel-level statement±30mm

rule validated

Operating conditions
sign
± magnitude; not a 1-sigma statistical measure
Source evidence
S2 | Accuracy: ±30mm

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar distance resolutionModel-level statement13mm

rule validated

Source evidence
S2 | Distance Resolution: 13mm

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar frame rateModel-level statement10HzRating: typical

rule validated

Operating conditions
qualifier source
Overview table explicitly labels rotational speed and angular resolution typical
Source evidence
S2 | Scan Rate: 10Hz

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar point rateModel-level statement32000 times per secord

rule validated

Source evidence
S2 | Sample Rate: 32000 times per secord

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar powerModel-level statement> 2W

rule validated

Operating conditions
comparison
Unnormalized lower-bound statement; not maximum consumption
Source evidence
S2 | Power Consumption: > 2W

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar range 10 reflectivityModel-level statement0.05-10m(10% reflection)Rating: maximum

rule validated

Operating conditions
minimum distance m
0.05
target reflectivity percent
10
Source evidence
S2 | Distance Range: 0.05-10m(10% reflection)

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar range 90 reflectivityModel-level statement0.05-30m(90% reflection)Rating: maximum

rule validated

Operating conditions
minimum distance m
0.05
target reflectivity percent
90
Source evidence
S2 | Distance Range: 0.05-30m(90% reflection)

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Lidar scan flatnessModel-level statement±1.5°

rule validated

Operating conditions
sign
± magnitude; not a 1-sigma statistical measure
Source evidence
S2 | Scan Field Flatness: ±1.5°

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Nominal supply voltageModel-level statement5V

rule validated

Source evidence
S2 | System Voltage: 5V

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Operating temperature rangeModel-level statement-10℃-50℃

rule validated

Source evidence
S2 | Temperature Range: -10℃-50℃

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Sensor interfaceModel-level statementURAT Serial(1M)

rule validated

Source evidence
S2 | Communication Interface: URAT Serial(1M)

table.a3-parameter-table column 2

Source observed: 2026-10-13View source
Vision ingress protectionModel-level statementIP65

rule validated

Source evidence
S2 | Proof Level: IP65

table.a3-parameter-table column 2

Source observed: 2026-10-13View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error