PartMeld

Kollmorgen Corporation

TBM2G-06826A

Model / article: TBM2G-06826A

TBM2G-06826A is listed by Kollmorgen Corporation in Frameless torque motors. Published model data includes Continuous output torque: 1.54 Nm (continuous); Rated output torque: 1.53 Nm (rated). See the specification table for operating conditions and source evidence.

Published base-motor/winding configurations. Thermal device, Hall sensor, leads and custom options must be specified separately.

Family image
Family image

Product overview

Manufacturer / supplier
Kollmorgen Corporation
Series
TBM2G 068 frameless torque motors
Component type
Frameless torque motors
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for TBM2G-06826A
SpecificationPublished valueConditions and source
RMS back-EMF constantModel-level statement30.0 Vrms/krpm

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
+/-10%
winding
A
winding temperature c
25
Source evidence
TBM2G-06826A | Cold Back EMF Constant: 30.0 Vrms/krpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 25, 'tolerance': '+/-10%', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Cold Back EMF Constant

Source observed: 2026-09-13View source
RMS back-EMF constantModel-level statement26.7 Vrms/krpm

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
+/-10%
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Hot Back EMF Constant: 26.7 Vrms/krpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 155, 'tolerance': '+/-10%', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Hot Back EMF Constant

Source observed: 2026-09-13View source
Continuous RMS currentModel-level statement3.48 ArmsRating: continuous

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
winding temperature c
155
winding temperature rise c
130
Source evidence
TBM2G-06826A | Max Cont. Current for ΔT wdg. = 130°C: 3.48 Arms | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_rise_c': 130, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Max Cont. Current for ΔT wdg. = 130°C

Source observed: 2026-09-13View source
Continuous RMS currentModel-level statement2.50 ArmsRating: continuous

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
winding temperature c
85
winding temperature rise c
60
Source evidence
TBM2G-06826A | Max Cont. Current for ΔT wdg. = 60°C: 2.50 Arms | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_rise_c': 60, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Max Cont. Current for ΔT wdg. = 60°C

Source observed: 2026-09-13View source
Continuous output torqueModel-level statement1.54 NmRating: continuous

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
winding temperature c
155
winding temperature rise c
130
Source evidence
TBM2G-06826A | Max Cont. Torque for ΔT wdg. = 130°C: 1.54 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_rise_c': 130, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Max Cont. Torque for ΔT wdg. = 130°C

Source observed: 2026-09-13View source
Continuous output torqueModel-level statement1.19 NmRating: continuous

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
winding temperature c
85
winding temperature rise c
60
Source evidence
TBM2G-06826A | Max Cont. Torque for ΔT wdg. = 60°C: 1.19 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_rise_c': 60, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Max Cont. Torque for ΔT wdg. = 60°C

Source observed: 2026-09-13View source
Lamination stack heightModel-level statement26.3 mm

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
Source evidence
TBM2G-06826A | Lamination stack height: 26.3 mm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately'}

PDF p.8 / TBM2G-06826A / Lamination stack height

Source observed: 2026-09-13View source
Line-to-line q-axis inductanceModel-level statement3.51 mH

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
+/-20%
winding
A
winding temperature c
null
Source evidence
TBM2G-06826A | Inductance Q-Axis (line-line): 3.51 mH | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': None, 'tolerance': '+/-20%', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Inductance Q-Axis (line-line)

Source observed: 2026-09-13View source
Line-to-line resistanceModel-level statement2.60 Ω

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
+/-10%
winding
A
winding temperature c
25
Source evidence
TBM2G-06826A | Resistance (line-line): 2.60 Ω | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 25, 'tolerance': '+/-10%', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Resistance (line-line)

Source observed: 2026-09-13View source
Product massModel-level statement0.462 kg

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
estimated
true
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
Source evidence
TBM2G-06826A | Weight: 0.462 kg | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'estimated': True, 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Weight

Source observed: 2026-09-13View source
Maximum output speedModel-level statement8000 rpm

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
rating basis
mechanical speed limit
winding
A
Source evidence
TBM2G-06826A | Max mechanical speed: 8000 rpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'rating_basis': 'mechanical speed limit', 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Max mechanical speed

Source observed: 2026-09-13View source
Motor constantModel-level statement0.251 Nm/√W

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
nominal
winding
A
winding temperature c
25
Source evidence
TBM2G-06826A | Motor Constant: 0.251 Nm/√W | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 25, 'tolerance': 'nominal', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Motor Constant

Source observed: 2026-09-13View source
Nominal supply voltageModel-level statement48 Vdc

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage definition
rated equivalent line voltage
winding
A
Source evidence
TBM2G-06826A | Rated Equivalent Line Voltage: 48 Vdc | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_definition': 'rated equivalent line voltage', 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Equivalent Line Voltage

Source observed: 2026-09-13View source
Outer diameterModel-level statement68 mm

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
Source evidence
TBM2G-06826A | Frame outer diameter: 68 mm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately'}

PDF p.8 / TBM2G-06826A / Frame outer diameter

Source observed: 2026-09-13View source
Overall lengthModel-level statement36.44 mmRating: maximum

rule validated

Operating conditions
assembly clearance
provide 0.25 mm minimum from solder and heat stakes
reference dimensions
true
Source evidence
TBM2G-06826A | Dimension A maximum: 36.44 mm | {'reference_dimensions': True, 'assembly_clearance': 'provide 0.25 mm minimum from solder and heat stakes'}

PDF p.26 / TBM2G-06826A / Dimension A maximum

Source observed: 2026-09-13View source
Peak RMS currentModel-level statement10.0 ArmsRating: peak

extracted

Operating conditions
ambient temperature c
25
commutation
sinusoidal
duration note
not published; verify allowable operating time
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
Source evidence
TBM2G-06826A | Peak Current: 10.0 Arms | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'duration_note': 'not published; verify allowable operating time', 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Peak Current

Source observed: 2026-09-13View source
Peak output torqueModel-level statement3.96 NmRating: peak

extracted

Operating conditions
ambient temperature c
25
commutation
sinusoidal
duration note
not published; verify allowable operating time
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Peak Torque: 3.96 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 155, 'duration_note': 'not published; verify allowable operating time', 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Peak Torque

Source observed: 2026-09-13View source
Pole pairsModel-level statement10

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
Source evidence
TBM2G-06826A | Pole Pairs: 10 | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Pole Pairs

Source observed: 2026-09-13View source
Rated operating-point powerModel-level statement0.037 kWRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
24
winding
A
winding temperature c
85
Source evidence
TBM2G-06826A | Rated Power (speed): 0.037 kW | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 24, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Power (speed)

Source observed: 2026-09-13View source
Rated operating-point powerModel-level statement0.097 kWRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
48
winding
A
winding temperature c
85
Source evidence
TBM2G-06826A | Rated Power (speed): 0.097 kW | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 48, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Power (speed)

Source observed: 2026-09-13View source
Rated operating-point powerModel-level statement0.112 kWRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
48
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Rated Power (speed): 0.112 kW | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 48, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Power (speed)

Source observed: 2026-09-13View source
Rated operating-point powerModel-level statement0.016 kWRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
24
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Rated Power (speed): 0.016 kW | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 24, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Power (speed)

Source observed: 2026-09-13View source
Rated output speedModel-level statement700 rpmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
48
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Rated Speed: 700 rpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 48, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Speed

Source observed: 2026-09-13View source
Rated output speedModel-level statement300 rpmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
24
winding
A
winding temperature c
85
Source evidence
TBM2G-06826A | Rated Speed: 300 rpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 24, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Speed

Source observed: 2026-09-13View source
Rated output speedModel-level statement800 rpmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
48
winding
A
winding temperature c
85
Source evidence
TBM2G-06826A | Rated Speed: 800 rpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 48, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Speed

Source observed: 2026-09-13View source
Rated output speedModel-level statement100 rpmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
24
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Rated Speed: 100 rpm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 24, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Speed

Source observed: 2026-09-13View source
Rated output torqueModel-level statement1.53 NmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
48
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Rated Torque (speed): 1.53 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 48, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Torque (speed)

Source observed: 2026-09-13View source
Rated output torqueModel-level statement1.19 NmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
24
winding
A
winding temperature c
85
Source evidence
TBM2G-06826A | Rated Torque (speed): 1.19 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 24, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Torque (speed)

Source observed: 2026-09-13View source
Rated output torqueModel-level statement1.54 NmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
24
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Rated Torque (speed): 1.54 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 24, 'winding_temperature_c': 155, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Torque (speed)

Source observed: 2026-09-13View source
Rated output torqueModel-level statement1.16 NmRating: rated

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
voltage v
48
winding
A
winding temperature c
85
Source evidence
TBM2G-06826A | Rated Torque (speed): 1.16 Nm | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'voltage_v': 48, 'winding_temperature_c': 85, 'winding': 'A'}

PDF p.22 / TBM2G-06826A / Rated Torque (speed)

Source observed: 2026-09-13View source
Rotor inertiaModel-level statement0.518 kg-cm2

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
estimated
true
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
Source evidence
TBM2G-06826A | Inertia: 0.518 kg-cm2 | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'estimated': True, 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Inertia

Source observed: 2026-09-13View source
Thermal resistanceModel-level statement1.83 °C/W

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
estimated
false
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
winding
A
Source evidence
TBM2G-06826A | Thermal Resistance: 1.83 °C/W | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'estimated': False, 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Thermal Resistance

Source observed: 2026-09-13View source
Clear through-bore diameterModel-level statement34.01–34.04 mm

rule validated

Operating conditions
reference dimensions
true
Source evidence
TBM2G-06826A | Rotor bore tolerance: 34.01–34.04 mm

PDF p.26 / TBM2G-06826A / Rotor bore tolerance

Source observed: 2026-09-13View source
RMS torque constantModel-level statement0.496 Nm/Arms

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
+/-10%
winding
A
winding temperature c
25
Source evidence
TBM2G-06826A | Cold Torque Constant: 0.496 Nm/Arms | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 25, 'tolerance': '+/-10%', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Cold Torque Constant

Source observed: 2026-09-13View source
RMS torque constantModel-level statement0.442 Nm/Arms

rule validated

Operating conditions
ambient temperature c
25
commutation
sinusoidal
installation
with housing and heat sink; without leads
ordering scope
base motor and winding; options must be specified separately
tolerance
+/-10%
winding
A
winding temperature c
155
Source evidence
TBM2G-06826A | Hot Torque Constant: 0.442 Nm/Arms | {'ambient_temperature_c': 25, 'commutation': 'sinusoidal', 'installation': 'with housing and heat sink; without leads', 'ordering_scope': 'base motor and winding; options must be specified separately', 'winding_temperature_c': 155, 'tolerance': '+/-10%', 'winding': 'A'}

PDF p.23 / TBM2G-06826A / Hot Torque Constant

Source observed: 2026-09-13View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error