PartMeld

SPINEA

TS110E

Model / article: TS110E

TS110E is listed by SPINEA in Cycloidal reducers. Published model data includes Rated output torque: 122 (rated); Product mass: 3,7. See the specification table for operating conditions and source evidence.

High-precision reduction gear with flange-shaped case and integrated radial/axial bearings; published for robotic and general automation applications.

E-series representative product illustration; not a configured-model image
E-series representative product illustration; not a configured-model image

Product overview

Manufacturer / supplier
SPINEA
Series
TwinSpin E series
Component type
Cycloidal reducers
Source
Open published source

Published pricing

No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.

Published specifications

Values are shown as published. Conditions, rating basis and source evidence apply to each value.

Latest source observation: . Observation dates record evidence collection, not supplier re-verification.

Specifications and source evidence for TS110E
SpecificationPublished valueConditions and source
Acceleration torqueModel-level statement244Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
load case
Acceleration and braking; no duration stated
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Acceleration and braking torque: 244 Nm

HTML table[3], tr[7], source cell[4]; expanded column 4; TS110E

Source observed: 2026-10-14View source
Allowable momentModel-level statement740Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
load case
Fa=0; for Fa≠0 consult manufacturer tilting-moment chapter
nominal life
L10 =6000 [Hrs]
output speed rpm
15
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Max. tilting moment 2)3): 740 Nm

HTML table[4], tr[7], source cell[6]; expanded column 6; TS110E

Source observed: 2026-10-14View source
Available ratiosModel-level statement33, 67, 119

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Ratio: 33, 67, 119

HTML table[2], tr[5], source cell[2]; expanded column 3; TS110E

Source observed: 2026-10-14View source
Permitted axial loadModel-level statement13,1Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
load case
Mc=0; for Mc≠0 consult manufacturer tilting-moment chapter
nominal life
L10 =6000 [Hrs]
output speed rpm
15
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Max. axial force 2)4): 13,1 kN

HTML table[4], tr[7], source cell[8]; expanded column 8; TS110E

Source observed: 2026-10-14View source
Backdrive torqueModel-level statement28Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
67
temperature
Nominal operating temperature; numerical value not stated in HTML
temperature condition
Below 20°C produces higher no-load starting/back-driving torque
Source evidence
TS110E | Max. back driving torque 9): 28 Nm

HTML table[3], tr[8], source cell[5]; expanded column 12; TS110E

Source observed: 2026-10-14View source
Backdrive torqueModel-level statement33Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
119
temperature
Nominal operating temperature; numerical value not stated in HTML
temperature condition
Below 20°C produces higher no-load starting/back-driving torque
Source evidence
TS110E | Max. back driving torque 9): 33 Nm

HTML table[3], tr[9], source cell[4]; expanded column 12; TS110E

Source observed: 2026-10-14View source
Backdrive torqueModel-level statement24Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
33
temperature
Nominal operating temperature; numerical value not stated in HTML
temperature condition
Below 20°C produces higher no-load starting/back-driving torque
Source evidence
TS110E | Max. back driving torque 9): 24 Nm

HTML table[3], tr[7], source cell[12]; expanded column 12; TS110E

Source observed: 2026-10-14View source
Emergency stop torqueModel-level statement610Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
load case
Permissible torque at emergency stop; not a safety certification
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Permissible torque at emergency stop: 610 Nm

HTML table[3], tr[7], source cell[5]; expanded column 5; TS110E

Source observed: 2026-10-14View source
Input inertiaModel-level statement0,16

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
informative
true
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
version dependency
Exact value depends on specific version
Source evidence
TS110E | Input inertia 8): 0,16 10^-4 kg m²

HTML table[4], tr[7], source cell[9]; expanded column 9; TS110E

Source observed: 2026-10-14View source
Lost motionModel-level statement<1,0Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
upper bound exclusive
true
Source evidence
TS110E | Max. lost motion: <1,0 arcmin

HTML table[4], tr[7], source cell[3]; expanded column 3; TS110E

Source observed: 2026-10-14View source
Product massModel-level statement3,7

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
informative
true
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
version dependency
Exact value depends on specific version
Source evidence
TS110E | Weight 8): 3,7 kg

HTML table[4], tr[7], source cell[10]; expanded column 10; TS110E

Source observed: 2026-10-14View source
Maximum input speedModel-level statement3500Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
33
speed condition
Depends on duty cycle; consult manufacturer for maximum speed; PDF calls it instantaneous speed peak within cycle
supporting source url
https://www.spinea.com/svc/stream/media/downloads/Catalogue%20lists/E
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Max. allowable input speed10): 3500 rpm

HTML table[3], tr[7], source cell[8]; expanded column 8; TS110E

Source observed: 2026-10-14View source
Maximum input speedModel-level statement3900Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
67
speed condition
Depends on duty cycle; consult manufacturer for maximum speed; PDF calls it instantaneous speed peak within cycle
supporting source url
https://www.spinea.com/svc/stream/media/downloads/Catalogue%20lists/E
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Max. allowable input speed10): 3900 rpm

HTML table[3], tr[8], source cell[3]; expanded column 8; TS110E

Source observed: 2026-10-14View source
Maximum input speedModel-level statement4500Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
119
speed condition
Depends on duty cycle; consult manufacturer for maximum speed; PDF calls it instantaneous speed peak within cycle
supporting source url
https://www.spinea.com/svc/stream/media/downloads/Catalogue%20lists/E
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Max. allowable input speed10): 4500 rpm

HTML table[3], tr[9], source cell[2]; expanded column 8; TS110E

Source observed: 2026-10-14View source
Permitted radial loadModel-level statement9,3Rating: rated

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
output speed rpm
15
published ratio options
["33","67","119"]
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Rated radial force 2): 9,3 kN

HTML table[4], tr[7], source cell[7]; expanded column 7; TS110E

Source observed: 2026-10-14View source
Rated output torqueModel-level statement122Rating: rated

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
rated input speed rpm
2000
temperature
Nominal operating temperature; numerical value not stated in HTML
Source evidence
TS110E | Rated output torque: 122 Nm

HTML table[3], tr[7], source cell[3]; expanded column 3; TS110E

Source observed: 2026-10-14View source
Starting torqueModel-level statement0,35Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
67
temperature
Nominal operating temperature; numerical value not stated in HTML
temperature condition
Below 20°C produces higher no-load starting/back-driving torque
Source evidence
TS110E | Max. no-load starting torque 9): 0,35 Nm

HTML table[3], tr[8], source cell[4]; expanded column 11; TS110E

Source observed: 2026-10-14View source
Starting torqueModel-level statement0,20Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
119
temperature
Nominal operating temperature; numerical value not stated in HTML
temperature condition
Below 20°C produces higher no-load starting/back-driving torque
Source evidence
TS110E | Max. no-load starting torque 9): 0,20 Nm

HTML table[3], tr[9], source cell[3]; expanded column 11; TS110E

Source observed: 2026-10-14View source
Starting torqueModel-level statement0,35Rating: maximum

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
ratio
33
temperature
Nominal operating temperature; numerical value not stated in HTML
temperature condition
Below 20°C produces higher no-load starting/back-driving torque
Source evidence
TS110E | Max. no-load starting torque 9): 0,35 Nm

HTML table[3], tr[7], source cell[11]; expanded column 11; TS110E

Source observed: 2026-10-14View source
Torsional stiffnessModel-level statement24

rule validated

Operating conditions
configuration scope
Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
dependencies
Version, ratio and lost motion
duty cycle
Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
nominal life
L10 =6000 [Hrs]
published ratio options
["33","67","119"]
statistic
Mean statistical value
temperature
Nominal operating temperature; numerical value not stated in HTML
version dependency
Parameter depends on reduction gear version
Source evidence
TS110E | Torsional stiffness 1)7): 24 Nm/arcmin

HTML table[3], tr[7], source cell[10]; expanded column 10; TS110E

Source observed: 2026-10-14View source

Technical documents and resources

Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.

Report a specification error