Ingenia Motion Control (Novanta)
CAP-NET-C
Model / article: CAP-NET-C
CAP-NET-C is listed by Ingenia Motion Control (Novanta) in Embedded servo drives. Published model data includes Product mass: 17.5 g; Maximum supply voltage: 60 VDC (continuous) (maximum). See the specification table for operating conditions and source evidence.
Capitan NET

Product overview
- Manufacturer / supplier
- Ingenia Motion Control (Novanta)
- Series
- Capitan NET
- Component type
- Embedded servo drives
- Source
- Open published source
Published pricing
No verified public price indexed for this model. Contact PartMeld for a supplier inquiry.
Published specifications
Values are shown as published. Conditions, rating basis and source evidence apply to each value.
Latest source observation: . Observation dates record evidence collection, not supplier re-verification.
| Specification | Published value | Conditions and source |
|---|---|---|
| Continuous output currentModel-level statement | 10 A Typically, 10 A can be obtained working at 48 V, 50 kHz with an appropriate cooling to keep case temperature under 85 ºC. On higher temperatures an automatic current derating will be applied to protect the system. See Thermal and Power Specifications below. For disambiguation on current definitions please see Disambiguation on current values and naming for Ingenia Drives.Rating: continuous | rule validated Operating conditions
Source evidenceCAP-NET-C | Maximum continuous phase current: 10 A Typically, 10 A can be obtained working at 48 V, 50 kHz with an appropriate cooling to keep case temperature under 85 ºC. On higher temperatures an automatic current derating will be applied to protect the system. See Thermal and Power Specifications below. For disambiguation on current definitions please see Disambiguation on current values and naming for Ingenia Drives. CAP-NET-C / Maximum continuous phase current |
| Drive dimensionsModel-level statement | 34.5 mm x 26 mm | rule validated Operating conditions
Source evidenceCAP-NET-C | Horizontal dimensions: 34.5 mm x 26 mm CAP-NET-C / Horizontal dimensions |
| Supported feedbackModel-level statement | Digital Halls Quadrature / Incremental encoder: Up to 2 at the same time. Absolute Encoder: up to 2 at the same time, combining any of the following: Dual BiSS-C (up to 2 in daisy chain topology or simultaneously) SSI EnDat 2.2 All feedback inputs are single-ended, 3.3 V logic levels. *Not all the existing absolute encoders are supported. Contact Ingenia for further information.Rating: maximum | rule validated Source evidenceCAP-NET-C | Feedbacks: Digital Halls Quadrature / Incremental encoder: Up to 2 at the same time. Absolute Encoder: up to 2 at the same time, combining any of the following: Dual BiSS-C (up to 2 in daisy chain topology or simultaneously) SSI EnDat 2.2 All feedback inputs are single-ended, 3.3 V logic levels. *Not all the existing absolute encoders are supported. Contact Ingenia for further information. CAP-NET-C / Feedbacks |
| Control networkModel-level statement | CiA-301, CiA-303, CiA-305, CiA-306 and CiA-402 (4.0) compliant. 125 kbps to 1 Mbps (default). Non-isolated. Termination resistor not included. Note: Ethernet port 1 can be used to configure the drive. | rule validated Source evidenceCAP-NET-C | CANopen / Ethernet (CAP-NET-C): CiA-301, CiA-303, CiA-305, CiA-306 and CiA-402 (4.0) compliant. 125 kbps to 1 Mbps (default). Non-isolated. Termination resistor not included. Note: Ethernet port 1 can be used to configure the drive. CAP-NET-C / CANopen / Ethernet (CAP-NET-C) |
| Drive operating temperatureModel-level statement | -20 ºC to +85 ºC | rule validated Operating conditions
Source evidenceCAP-NET-C | Ambient temperature (Operating): -20 ºC to +85 ºC CAP-NET-C / Ambient temperature (Operating) |
| Peak output currentModel-level statement | 20 A @ 1 sec Notice that peak current could be limited by an automatic current derating algorithm. In order to get 20 A, case temperature should be kept below 60 ºC.Rating: peak | rule validated Operating conditions
Source evidenceCAP-NET-C | Maximum peak phase current: 20 A @ 1 sec Notice that peak current could be limited by an automatic current derating algorithm. In order to get 20 A, case temperature should be kept below 60 ºC. CAP-NET-C / Maximum peak phase current |
| Maximum supply voltageModel-level statement | 60 VDC (continuous)Rating: maximum | rule validated Operating conditions
Source evidenceCAP-NET-C | Maximum DC bus supply voltage: 60 VDC (continuous) CAP-NET-C / Maximum DC bus supply voltage |
| Minimum supply voltageModel-level statement | 5 VDCRating: minimum | rule validated Operating conditions
Source evidenceCAP-NET-C | Minimum DC bus supply voltage: 5 VDC CAP-NET-C / Minimum DC bus supply voltage |
| Product massModel-level statement | 17.5 g | rule validated Source evidenceCAP-NET-C | Weight: 17.5 g CAP-NET-C / Weight |
Technical documents and resources
Confirm the exact configuration, price, availability and operating conditions with the supplier before ordering.