| Acceleration torqueModel-level statement | 100Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- load case
- Acceleration and braking; no duration stated
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Acceleration and braking torque: 100 Nm HTML table[3], tr[3], source cell[4]; expanded column 4; TS70E Source observed: 2026-10-14View source |
|---|
| Allowable momentModel-level statement | 142Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- load case
- Fa=0; for Fa≠0 consult manufacturer tilting-moment chapter
- nominal life
- L10 =6000 [Hrs]
- output speed rpm
- 15
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Max. tilting moment 2)3): 142 Nm HTML table[4], tr[3], source cell[6]; expanded column 6; TS70E Source observed: 2026-10-14View source |
|---|
| Available ratiosModel-level statement | 41, 75 | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Ratio: 41, 75 HTML table[2], tr[3], source cell[3]; expanded column 3; TS70E Source observed: 2026-10-14View source |
|---|
| Permitted axial loadModel-level statement | 4,1Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- load case
- Mc=0; for Mc≠0 consult manufacturer tilting-moment chapter
- nominal life
- L10 =6000 [Hrs]
- output speed rpm
- 15
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Max. axial force 2)4): 4,1 kN HTML table[4], tr[3], source cell[8]; expanded column 8; TS70E Source observed: 2026-10-14View source |
|---|
| Backdrive torqueModel-level statement | 13Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- ratio
- 75
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- temperature condition
- Below 20°C produces higher no-load starting/back-driving torque
Source evidenceTS70E | Max. back driving torque 9): 13 Nm HTML table[3], tr[4], source cell[5]; expanded column 12; TS70E Source observed: 2026-10-14View source |
|---|
| Backdrive torqueModel-level statement | 11Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- ratio
- 41
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- temperature condition
- Below 20°C produces higher no-load starting/back-driving torque
Source evidenceTS70E | Max. back driving torque 9): 11 Nm HTML table[3], tr[3], source cell[12]; expanded column 12; TS70E Source observed: 2026-10-14View source |
|---|
| Emergency stop torqueModel-level statement | 250Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- load case
- Permissible torque at emergency stop; not a safety certification
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Permissible torque at emergency stop: 250 Nm HTML table[3], tr[3], source cell[5]; expanded column 5; TS70E Source observed: 2026-10-14View source |
|---|
| Input inertiaModel-level statement | 0,061 | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- informative
- true
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- version dependency
- Exact value depends on specific version
Source evidenceTS70E | Input inertia 8): 0,061 10^-4 kg m² HTML table[4], tr[3], source cell[9]; expanded column 9; TS70E Source observed: 2026-10-14View source |
|---|
| Lost motionModel-level statement | <1,5Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- upper bound exclusive
- true
Source evidenceTS70E | Max. lost motion: <1,5 arcmin HTML table[4], tr[3], source cell[3]; expanded column 3; TS70E Source observed: 2026-10-14View source |
|---|
| Product massModel-level statement | 1 | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- informative
- true
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- version dependency
- Exact value depends on specific version
Source evidenceTS70E | Weight 8): 1 kg HTML table[4], tr[3], source cell[10]; expanded column 10; TS70E Source observed: 2026-10-14View source |
|---|
| Maximum input speedModel-level statement | 5000Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- ratio
- 75
- speed condition
- Depends on duty cycle; consult manufacturer for maximum speed; PDF calls it instantaneous speed peak within cycle
- supporting source url
- https://www.spinea.com/svc/stream/media/downloads/Catalogue%20lists/E
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Max. allowable input speed10): 5000 rpm HTML table[3], tr[4], source cell[3]; expanded column 8; TS70E Source observed: 2026-10-14View source |
|---|
| Maximum input speedModel-level statement | 4000Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- ratio
- 41
- speed condition
- Depends on duty cycle; consult manufacturer for maximum speed; PDF calls it instantaneous speed peak within cycle
- supporting source url
- https://www.spinea.com/svc/stream/media/downloads/Catalogue%20lists/E
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Max. allowable input speed10): 4000 rpm HTML table[3], tr[3], source cell[8]; expanded column 8; TS70E Source observed: 2026-10-14View source |
|---|
| Moment stiffnessModel-level statement | 40 | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- statistic
- Mean statistical value
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- version dependency
- Parameter depends on reduction gear version
Source evidenceTS70E | Tilting stiffness 1)6): 40 Nm/arcmin HTML table[3], tr[3], source cell[9]; expanded column 9; TS70E Source observed: 2026-10-14View source |
|---|
| Permitted radial loadModel-level statement | 2,8Rating: rated | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- output speed rpm
- 15
- published ratio options
- ["41","75"]
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Rated radial force 2): 2,8 kN HTML table[4], tr[3], source cell[7]; expanded column 7; TS70E Source observed: 2026-10-14View source |
|---|
| Rated output torqueModel-level statement | 50Rating: rated | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- rated input speed rpm
- 2000
- temperature
- Nominal operating temperature; numerical value not stated in HTML
Source evidenceTS70E | Rated output torque: 50 Nm HTML table[3], tr[3], source cell[3]; expanded column 3; TS70E Source observed: 2026-10-14View source |
|---|
| Starting torqueModel-level statement | 0,30Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- ratio
- 41
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- temperature condition
- Below 20°C produces higher no-load starting/back-driving torque
Source evidenceTS70E | Max. no-load starting torque 9): 0,30 Nm HTML table[3], tr[3], source cell[11]; expanded column 11; TS70E Source observed: 2026-10-14View source |
|---|
| Starting torqueModel-level statement | 0,14Rating: maximum | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- ratio
- 75
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- temperature condition
- Below 20°C produces higher no-load starting/back-driving torque
Source evidenceTS70E | Max. no-load starting torque 9): 0,14 Nm HTML table[3], tr[4], source cell[4]; expanded column 11; TS70E Source observed: 2026-10-14View source |
|---|
| Torsional stiffnessModel-level statement | 8 | rule validated Operating conditions- configuration scope
- Named E-series size model; ratio, shaft and flange selected separately; no complete ordering SKU inferred
- dependencies
- Version, ratio and lost motion
- duty cycle
- Preferred intermittent cycles S3–S8; inverted-variable output speed; continuous S1 requires manufacturer consultation
- nominal life
- L10 =6000 [Hrs]
- published ratio options
- ["41","75"]
- statistic
- Mean statistical value
- temperature
- Nominal operating temperature; numerical value not stated in HTML
- version dependency
- Parameter depends on reduction gear version
Source evidenceTS70E | Torsional stiffness 1)7): 8 Nm/arcmin HTML table[3], tr[3], source cell[10]; expanded column 10; TS70E Source observed: 2026-10-14View source |
|---|